Connect the hardware, and then turn on the system.
Caution Before connecting the hardware, confirm the following:
<1> Flipping the MINICUBE2 switches
Flip the MINICUBE2 switches to the following positions:
<2> Connecting a wireless unit to MINICUBE2
Connect the wireless unit that was set to "H" to MINICUBE2. Note the
direction when connecting the unit.
Next, perform wireless communication, use the wireless units, and then
check the firmware version and the radio wave status.
<1> Starting the RF utility
Run the mqb2rfutl.exe file that was downloaded and decompressed in
step 2. The following window is displayed.
<2> Specifying the basic settings for wireless communication (the
frequency channel and target unit ID)
Click [Option] on the menu bar and then [Configuration] to display the
configuration dialog box. Specify the frequency channel and target unit
ID, and then click the [OK] or [Apply] button.
After wireless communication ends, create a program in the same way as for a standard configuration in which the target cable is used. For example,
when starting debugging, start the debugger, download the program, and then perform debugging.
The radio wave status during wireless communication changes depending on external factors such as other used wireless devices. Such changes
can be determined using the RF utility. Be sure to use this product in an environment where radio waves are relatively stable.
We recommend reading the additional information on the following pages.
(1) Close the debugger or programming GUI.
(2) Close the RF utility.
To end debugging or programming, turn off the system according to the following procedure. Next, disconnect the wireless units as required.
Connecting and Starting Hardware
Establishing Wireless Communication and Checking Firmware
Starting Debugging and Programming
End Procedure
Flip the MINICUBE2
switches to positions
"M2" and "3".
-MINICUBE2 is not connected via USB.
-The target system is turned off.
MINICUBE2
Select any channel.
Select the unit ID of the
wireless unit connected to
the target system.
M1
M2
3
Wireless unit
T
5
<3> Connecting a wireless unit to the target system
Connect the wireless unit that was set to "T" to the target system. Note
the position of pin 1, because the wireless unit is not protected against
false connection. (The pin layout is shown in the figure to the right
below.)
<4> Starting the system
(1) Connect MINICUBE2 to the host by using a USB cable. The LED on
(2) Turn on the target system.
<3> Starting and checking wireless communication
Wireless communication starts when the basic settings have been
specified. After the settings are specified, they are held in the host
registry and automatically specified every time the host starts.
If wireless communication is successful, the radio wave status and
measured temperature are graphed in the main window.
If wireless communication was not successful, "Fail" is displayed on the
status bar. In this case, change the frequency channel and check the
target unit ID in the configuration dialog box.
<4> Checking the firmware version
Click [Help] on the menu bar and then [Version].
The firmware versions of the RF utility and wireless units are displayed.
On the Version-up Service website, check whether these are the latest
versions.
This concludes setting up wireless communication.
(3) Turn off the target system.
(4) Disconnect MINICUBE2 from the host.
The LED on the wireless unit turns on and off as in (1) above.
the wireless unit turns on and off.
Wireless unit
The radio wave status
and temperature are
graphed.
Target system
Text on status bar
• If communication is successful
• If communication is abnormal
Pin 1
Pin 2