DEMOKIT-LF3 Renesas Electronics America, DEMOKIT-LF3 Datasheet - Page 20

no-image

DEMOKIT-LF3

Manufacturer Part Number
DEMOKIT-LF3
Description
KIT DEMO 78K0 LF3 UPD78F0495
Manufacturer
Renesas Electronics America
Datasheet

Specifications of DEMOKIT-LF3

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DemoKit-LF3 User’s Manual
2.18 Soldering bridges
Additional configuration of the DemoKit-LF3 board can be done using the A1–A8 and V1–V11 soldering
bridges as described in the tables below. The A1–A8 and V7 soldering bridges can be used to
reconfigure the A/D converter input channels and the reference input voltage.
Table 11. Settings of A1—A8 and V7 soldering bridges
Soldering bridge
A1
A2
A3
A4
A5
A6
A7
A8
V7
Connector
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
Configuration
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
Closed (default)
Open
P13 / SO10 / TxD0
P33 / TIO00 / RTCDIV / RTCCL / BUZ / INTP2
P12 / SI10 / RxD0
P16 / SOA0 / TxD6
P30 / INTP5
P11 / SCK10
P15 / SIA0 / RxD6
Microcontroller I/O pins
P31 / TOH1 / INTP3
P10 / PCL
P120 / INTP0 / EXLVI
P47 / KR7
U18759EE1V0UMU1
ANI0/DS0-
ANI1/DS0+
ANI2/DS1-
ANI3/DS1+
ANI4/DS2-
ANI5/DS2+
ANI6/REF-
ANI7/REF+
AVREF
78K0/LF3 pin
Connected to V
Disconnected from V
Connected to temperature sensor U2
Disconnected from temperature sensor U2
Connected to V
Disconnected from V
Pin connected to jumper J2
Disconnected from jumper J2
Connected to V
Disconnected from V
Connected to V
Disconnected from V
Connected to V
Disconnected from V
Connected to V
Disconnected from V
Connected to V
Disconnected from V
SS
SS
SS
DD27
SS
DD
DD
SS
SS
SS
DD27
SS
DD
DD
12

Related parts for DEMOKIT-LF3