R0K42215RS001BE Renesas Electronics America, R0K42215RS001BE Datasheet - Page 13

KIT STARTER FOR H8S/2215R

R0K42215RS001BE

Manufacturer Part Number
R0K42215RS001BE
Description
KIT STARTER FOR H8S/2215R
Manufacturer
Renesas Electronics America
Series
H8®r
Type
MCUr

Specifications of R0K42215RS001BE

Contents
Evaluation Board
For Use With/related Products
H8S/2215
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 6-5 below describes the function of the option links associated with serial configuration. The default configuration is indicated by
BOLD text.
R6
R7
R19
R28
R29
R30
R31
R32
R33
R37
R38
Reference
6.6. Option Links
Serial Port
Configuration
Serial Port
Configuration
RS232 Serial
Serial Port
Configuration
Serial Port
Configuration
Serial Port
Configuration
Serial Port
Configuration
Serial Port
Configuration
Serial Port
Configuration
Serial Port
Configuration
Serial Port
Configuration
Function
Connects programming port (Rx) to E8
connector.
Connects programming port (Tx) to E8
connector.
Disables RS232 Serial
Transceiver
Connects serial port RXD0 to SERIAL
D-type connector.
Connects serial port TXD0 to SERIAL
D-type connector.
Routes RS232 serial port Rx to
application connector (JA6)
Routes RS232 serial port Tx to application
connector (JA6)
Connects serial port 1(Tx) to SERIAL
D-type (J8).
Connects serial port 1 (Rx) to D-type (J8).
Connects programming port (Rx) to
external connectors (not E8).
Connects programming port (Tx) to
external connectors (not E8).
Table 6-5: Serial configuration links
Fitted
Option Link Settings
11
Disconnects programming port (Rx)
from E8 connector.
Disconnects programming port (Tx)
from E8 connector.
Enables RS232 Serial
Transceiver
Disconnects serial port RXD0 from
SERIAL D-type connector.
Disconnects serial port TXD0 from
SERIAL D-type connector.
Disconnects RS232 serial port Rx
from application connector (JA6)
Disconnects RS232 serial port Tx
from application connector (JA6)
Disconnects serial port 1 (Tx) from
SERIAL D-type.
Disconnects serial port 1 (Rx) from
SERIAL D-type.
Disconnects programming port (Rx)
to external connectors (not E8).
Disconnects programming port (Tx)
to external connectors (not E8).
Alternative (Removed)
R7, R37,
R38
R6, R37,
R38
R29
R28
R31
R30
R16, R26,
R33
R16, R26,
R32
R6, R7,
R38
R6, R7,
R37
Related To

Related parts for R0K42215RS001BE