EDK2378 Renesas Electronics America, EDK2378 Datasheet - Page 4

DEV EVAL KIT FOR H8S/2378

EDK2378

Manufacturer Part Number
EDK2378
Description
DEV EVAL KIT FOR H8S/2378
Manufacturer
Renesas Electronics America
Series
H8®r
Type
MCUr
Datasheets

Specifications of EDK2378

Contents
2G (Second-generation) Evaluation Board, HEW debugger support, Cable and CD-ROM
For Use With/related Products
H8S/2378
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
EDK2378 Quickstart Guide
The following procedure explains how to connect to the EDK2378 and debug the project in HEW.
The EDK uses HMON to connect to HEW and debugging is carried out in User Programming Mode. The User Program
Mode jumper, marked UPM in CJ4 on the silkscreen on the board, does not need to be moved during user programming.
This is because there is no Flash write pin on the H8S/2378 device.
To run the program:
Congratulations! You have installed the software; programmed the EDK and run your first program with the debugger. To
continue learning about the tools and the board please read the EDK Tutorial Manual and supporting User Manuals
Kernel modification
A HEW EDK2378 kernel workspace containing user kernel source files and build configurations is provided on this CD.
To recompile the 2378 kernels using this workspace for a different crystal frequency, please refer to the User Manual section
7.2 for details of the additional steps required.
Technical Support
The EDK is a tool for evaluation purposes only. Technical support is limited to that which is provided on the Renesas
Technology Europe’s website at:
Renesas Technology Europe Ltd.
4
The Program Counter will go to the program start address, denoted by a yellow arrow.
Running the Debugger
Click on the HMON FLASH Download Setting button
Click on the USER radio button
Ensure that the “uKernel Address” is set to H’1000, and that the “Referenced Value” box is not checked. Ensure
that the “Return Address” is set to H’0, and that the “Referenced Value” box is checked, and click “OK”
Click “Save Session”, from the “File” menu.
Click “Build”, “Debug”, “Connect”.
The console window will report that the EDK has connected.
Right click on the “.abs” file in the “Download Module” section, and choose “Download Module”.
Double-click on the resetprg.c file in the HEW Project workspace window, under the “C Source File” folder.
The C code listing will appear with a margin at the left showing the areas in memory where the code has been
loaded.
Click on the “ResetCPU” button
Select the "Debug", "Reset Go" menu item.
Both the User LEDs on the EDK will start flashing.
http://www.eu.renesas.com/tools
.
.
.
D004886_11_v02