AS1110 EB austriamicrosystems, AS1110 EB Datasheet - Page 11

no-image

AS1110 EB

Manufacturer Part Number
AS1110 EB
Description
BOARD EVAL AS1110
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS1110 EB

Current - Output / Channel
0.5 ~ 100 mA
Outputs And Type
16, Non-Isolated
Voltage - Output
0 ~ 15 V
Features
Over-Temperature, Open-LED, Shorted-LED, Diagnostics
Voltage - Input
3 ~ 5.5 V
Utilized Ic / Part
AS1110
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
AS1110
Datasheet - D e t a i l e d D e s c r i p t i o n
Figure 13. Switching Global Error Mode Timing Diagram
Error-Detection Mode
Acquisition of the error status occurs at the rising edge of OEN. Error-detection mode is started on the rising edge of
LD when OEN is high. The CLK signal must be low when entering error detection mode. Error detection for open- and
shorted-LEDs can only be performed for LEDs that are switched on during test time. To switch between error-detection
modes clock pulses are needed
Note: To test all LEDs, a test pattern that turns on all LEDs must be input to the AS1110.
Global Error Mode
Global error mode is entered when error-detection mode is started. Clock pulses during this period are used to select
between temperature, open-LED, and shorted-LED tests, as well as low-current diagnostic mode and shutdown mode
(see Table
encountered.
Table 5. Global Error Mode Selections
Note: For a valid result SDI must be 1 for the first device.
www.austriamicrosystems.com/LED-Driver-ICs/AS1110
Pulses
Clock
OEN
SDO
CLK
SDI
0
1
2
3
4
LD
Output Port
Don't Care
Don't Care
Don't Care
5). In global error mode, an error flag (T
Enabled
Enabled
t
SU(ERROR)
t
TESTING
Acquisition of
Error Status
Low-Current Diagnostic
Error-Detection Mode
Shorted-LED Detection
t
Open-LED Detection
GSW(ERROR)
Over-Temperature
Shutdown Mode
(see Table
Detection
Mode
t
P4
5).
Don’t
Care
t
P(I/O)
t
GSW(ERROR)
FLAG,
T
T
O
O
S
S
SDI = 1: Wakeup
SDI = 0: Shutdown
FLAG
FLAG
FLAG
FLAG
FLAG
FLAG
Revision 1.05
T
O
FLAG(IN)
FLAG,
t
= SDO = 1: No over-temperature warning.
= SDO = 0: Over-temperature warning.
= SDO = 1: No shorted-LED error.
= SDO = 0: Shorted-LED error.
SW(ERROR)
= SDO = 1: No open-LED error.
= SDO = 0: Open-LED error.
T
FLAG
S
Global Error Flag/Shutdown Condition
FLAG
) is delivered to pin SDO if any errors are
Don’t
Care
t
P(I/O)
O
FLAG(IN)
O
FLAG
Don’t
Care
t
P(I/O)
t
SW(ERROR)
S
t
GSW(ERROR)
FLAG(IN)
S
FLAG
11 - 24

Related parts for AS1110 EB