MAX17007EVKIT+ Maxim Integrated Products, MAX17007EVKIT+ Datasheet - Page 3

no-image

MAX17007EVKIT+

Manufacturer Part Number
MAX17007EVKIT+
Description
KIT EVAL FOR MAX17007
Manufacturer
Maxim Integrated Products
Series
Quick-PWM™r

Specifications of MAX17007EVKIT+

Main Purpose
DC/DC, Step Down
Outputs And Type
2, Non-Isolated
Voltage - Output
1.2V, 1.5V
Current - Output
12A, 12A
Voltage - Input
7 ~ 24V
Regulator Topology
Buck
Frequency - Switching
270kHz, 330kHz
Board Type
Fully Populated
Utilized Ic / Part
MAX17007
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Before beginning, the following equipment is needed:
The MAX17007A EV kit is fully assembled and tested.
Follow the steps below to verify board operation.
Caution: Do not turn on the power supplies until all
connections are completed.
1) Ensure that the EV kit is connected correctly to the
2) Verify that shunts are installed according to Table 1.
3) Turn on battery power prior to 5V DC bias power;
4) Verify that the PGOOD1 and PGOOD2 LEDs (D3
The MAX17007A EV kit demonstrates the features of
the MAX17007A dual step-down controller. The EV kit
provides a dynamic 1V/1.2V OUT1 voltage and a preset
1.5V OUT2 voltage from a 7V to 24V input. Each output
provides up to a 12A load current. The OUT1 and
OUT2 outputs are configured to operate at switching
frequencies of 270kHz and 330kHz, respectively.
Table 1. Default Jumper Settings
Note: JU6 (ILIM1) and JU5 (ILIM2) are prewired for current
limits of 30mV.
Detailed Description of Hardware
JUMPER
7V to 24V, 10A power supply, battery, or notebook
AC adapter (V
DC bias power supply, 5V at 100mA (V
Digital multimeter
supplies prior to enabling the power supplies.
otherwise, the output UVLO timer times out and the
FAULT latch is set, disabling the regulator until 5V
power is cycled below 0.5V or EN is toggled.
and D4) are lit and that the OUT1 voltage measures
1.2V and the OUT2 voltage measures 1.5V.
JU1
JU2
JU3
JU4
JU7
JU8
POSITION
IN
_______________________________________________________________________________________
Installed
Installed
Installed
SHUNT
)
2-3
1-2
1-3
Recommended Equipment
CONFIGURATION
V
V
Forced-PWM mode
OUT1 enabled
OUT2 enabled
OUT1
OUT2
= 1.2V
= 1.5V
Quick Start
Procedure
DD
)
MAX17007A Evaluation Kit
The OUT1 output can also be configured for a preset
1.05V (REFIN1 = VDD), adjustable between 0 to 2V, or
different dynamic output voltages. The OUT2 output
can be configured for preset 1.5V (FB2 = REF) or
adjustable from 0.7V to 2V by installing appropriate
feedback resistors. See the OUT1 Voltage (V
OUT2 Voltage (V
The outputs can also be combined to operate as a two-
phase, high-current, single-output regulator. In this
mode the output is configured for either a preset,
adjustable, or dynamically adjustable output voltage
using REFIN1. See the Combined-Mode Operation sec-
tion for more details.
The MAX17007A EV kit provides access to the device’s
enable control pins (EN1 and EN2), through jumpers
JU7 and JU8, respectively. EN1 is used to control the
OUT1 output and EN2 is used to control the OUT2 out-
put. When in combined mode, EN1 is used for output
control and EN2 must be connected to GND. Tables 2
and 3 list the selectable jumper options for each output-
enable pin.
The EN1 and EN2 control pins can also be driven by an
external signal by removing the shunt from JU7 or JU8
and connecting the control signal to the EN1 or EN2
test point. The output operation will depend on the
external control-signal level.
Table 2. Jumper JU7 Functions
* Default position.
Table 3. Jumper JU8 Functions
* Default position.
Not installed
Not installed
POSITION
POSITION
SHUNT
SHUNT
1-2*
1-2*
OUT2
Connected to GND
Connected to GND
Connected to VDD
Connected to VDD
through R14
through R15
EN1 PIN
EN2 PIN
) sections for more details.
Output Enable (EN1, EN2)
Enabled
(V
Shutdown mode
(V
Enabled
(V
Shutdown mode
(V
OUT1
OUT1
OUT2
OUT2
OUT1 OUTPUT
OUT2 OUTPUT
= 1V/1.2V)
= 0V)
= 1.5V)
= 0V)
OUT1
) and
3

Related parts for MAX17007EVKIT+