MCP355XDM-TAS Microchip Technology, MCP355XDM-TAS Datasheet - Page 15

BOARD DEMO TINY APP SNSR MCP355X

MCP355XDM-TAS

Manufacturer Part Number
MCP355XDM-TAS
Description
BOARD DEMO TINY APP SNSR MCP355X
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP355XDM-TAS

Number Of Adc's
1
Number Of Bits
22
Data Interface
Serial
Inputs Per Adc
1 Single Ended
Input Range
±3 V
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Utilized Ic / Part
MCP355x
Processor To Be Evaluated
MCP355x
Interface Type
USB
Silicon Manufacturer
Microchip
Silicon Core Number
MCP3551, MCP3553, MCP3550-50, MCP3550-60
Kit Application Type
Data Converter
Application Sub Type
ADC
Kit Contents
Board Cable Docs
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Not applicable / Not applicable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Not applicable / Not applicable

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP355XDM-TAS
Manufacturer:
MICROCHIP
Quantity:
12 000
© 2006 Microchip Technology Inc.
FIGURE 2-4:
2.4.6
The Sample Rate demo uses a combination of polling and time to sample the input
signal. When the Play button in the software is pressed, the PIC18F4550 samples the
Ready state of the MCP3551 every 10 ms by lowering CS and sampling the SDO/RDY
pin. If the device is ready (i.e., the conversion is complete), the data is clocked out.
Otherwise, CS is raised.
Since the conversion time of the MCP3551 is ~72 ms and the Ready state is sampled
at ~10 ms intervals, the data is available to the PC approximately every 72 ms, ±10 ms.
However, the USB host queries the board for data every 10 ms. This implies that the
minimum sample rate for the software (see Section 2.4.5.4 “Configuration Window”
for details on setting the sample rate) should be > 92 ms (or ~100 ms). If the DataView
software is set to a shorter sample rate, data will be repeated and the software will not
reflect the true operation of the device.
See the MCP3550/1/3 Data Sheet (DS21950) for more details on conversion time and
Single Conversion mode.
Note:
MCP3551 Sample Rate Demo
Once data is read out and CS is toggled for the first time, the device is
placed in Single Conversion mode.
Auxilary Data Window.
DS51579C-page 11

Related parts for MCP355XDM-TAS