An ADC scan measures all enabled cell inputs, all
enabled auxiliary inputs, and the self-diagnostics
channel (if enabled). The conversion begins once the
STROBE bit in the ADCCFG register is set. The following
procedure outlines the steps to set up and initiate single
or continuous ADC scanning.
Set_Up:
1) Enable the cells to measure:
Note: The cell channels can also be enabled with the
checkboxes on the Voltage_Measurements tab.
2) Select the cell registers to read:
3) Enable the self-diagnostics and auxiliary inputs to
4) Select the self-diagnostics and auxiliary input regis-
Initiate_a_Single_ADC_Scan:
1) Check the SCAN checkbox on the Enables tab, then
2) Select the Voltage_ Measurements tab and press
Note: The STROBE bit is automatically set before a read
is done on the Voltage_Measurements tab.
Initiate_Continuous_ADC_Scanning:
1) Select the Read/Scan tab.
2) Enter the time delay between ADC scans into the
3) Check the Enable_ADC_scanning checkbox.
Note: To save the data during a continuous ADC scan,
perform the steps from the Log Scanned Data section in
place of these steps.
measure:
ters for reading:
press the Configure_All_Devices button, or
F8 (Refresh) or F7 (Read All Selected) to read the
selected cell registers.
Interval_(msec) edit box.
• Check the CELL_EN checkboxes on the
• Press the Configure_Cells_(F9) button.
• Check the CELL_ checkboxes on the Voltage_
• Check the DIAGEN,_AIN2EN, and AIN1EN_
• Press the Configure_Active_Device or the
• Check the AIN1,_AIN2, and DIAG checkboxes
Configuration tab in the ADC_Scan_(CELLEN)_–_
Global_Setting group box.
Measurements tab.
checkboxes on the Enables tab in the General_
Configuration_(ADCCFG) group box.
Configure_All_Devices button.
on the AIN1/DIAG/FMEA tab.
_______________________________________________________________________________________ _ 21
ADC Scan
MAX11068 Evaluation System
The EV kit software allows the data, measured during
continuous ADC scanning, to be saved to file. This fea-
ture is available by selecting the File_ |_ Log_ Scan_ Data
menu item and should be set up before scanning is start-
ed. The steps below explain how to set up data logging:
1) Perform steps 1–4 in the ADC Scan section.
2) Select the File_|_Log_Scan_Data_menu_item or press
3) Enter the number (n) of ADC scans to record, and
4) Select the Read/Scan tab.
5) Enter the time delay between ADC scans into the
6) Check the Enable_ ADC_ scanning checkbox. A red
7) Once n number of scans have been completed, the
8) A Log_ Data dialog box appears. The default file
At the completion of this process, data logging is dis-
abled, but the continuous ADC scanning continues until
the Enable_ADC_Scanning checkbox is unchecked. The
file generated by the software logs the measured data of
the enabled channels for all the devices in the SMBus
ladder.
CTRL+L. The following window appears:
then press Enter.
Interval_(msec) edit box.
Logging_ Data label appears, notifying that data is
being recorded.
Log_Complete window appears. Press OK.
name is 11068all and the default file type is .xls
(Excel spreadsheet). If a different name or file type is
preferred, enter it into the File_name edit field. Press
Save.
Log Scanned Data