KIT15XS3400EVBE Freescale Semiconductor, KIT15XS3400EVBE Datasheet - Page 30

BOARD EVALUATION FOR 5XS3400

KIT15XS3400EVBE

Manufacturer Part Number
KIT15XS3400EVBE
Description
BOARD EVALUATION FOR 5XS3400
Manufacturer
Freescale Semiconductor
Type
MOSFET & Power Driverr
Datasheets

Specifications of KIT15XS3400EVBE

Main Purpose
Automotive Lighting
Embedded
No
Utilized Ic / Part
MC15XS3400
Primary Attributes
Four low RDS(ON) MOSFETs
Secondary Attributes
Temperature Protection
Interface Type
SPI
Product
Power Management Modules
Silicon Manufacturer
Freescale
Silicon Core Number
MC15XS3400
Kit Application Type
Power Management
Application Sub Type
EXtreme Switch
Kit Contents
Board, CD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
15XS3400
FAULT MODE
driving the
fault condition is removed, except for over-current, severe
short-circuit, over-temperature and under-voltage which will
be reset by a new turn-on command (each fault_control
signal to be toggled).
available (and reset) via the SO pin during the first valid SPI
communication.
30
15XS3400
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
The 15XS3400 is in Fault mode when:
• V
• wake-up = 1,
• fail = X,
• fault=1.
This device indicates the faults below as they occur by
• Over-temperature fault,
• Over-current fault,
• Severe short-circuit fault,
• Output(s) shorted to VPWR fault in OFF state,
• Open load fault in OFF state,
• Over-voltage fault (enabled by default),
• Under-voltage fault.
The
Fault information is retained in the SPI fault register and is
PWR
FS
pin will automatically return to logic [1] when the
FS
and V
pin to logic [0] for RST input is pulled up:
DD
are within the normal voltage range,
SPI register without effect on the corresponding output state
(HS[x]) and the
START-UP SEQUENCE
following sequence is provided:
set to logic [1]) with an external reference clock:
function is not guaranteed.
The Open load fault in ON state is only reported through
The 15XS3400 enters in Normal mode after start-up if
•VPWR and VDD power supplies must be above their
•generate wake-up event (wake-up=1) from 0 to 1 on
And, in case of the PWM module is used (PWM_en bit is
•apply PWM clock on IN0 input pin after maximum 200 μs
If the correct start-up sequence is not provided, the PWM
under-voltage thresholds,
RSTB. The device switches to Normal mode with SPI
register content is reset (as defined in
Table
after 50 μs typical and all SPI registers are set to default
values (set to logic [0]). The UV fault is reported in the
SPI status registers.
(min. 50 μs).
23). All features of 15XS3400 will be available
FS
pin.
Analog Integrated Circuit Device Data
Freescale Semiconductor
Table 11
and

Related parts for KIT15XS3400EVBE