CRD8900A-1 Cirrus Logic Inc, CRD8900A-1 Datasheet - Page 54

no-image

CRD8900A-1

Manufacturer Part Number
CRD8900A-1
Description
KIT EVAL FOR CS8900A
Manufacturer
Cirrus Logic Inc
Series
CrystalLAN™r
Datasheet

Specifications of CRD8900A-1

Main Purpose
Interface, Ethernet
Utilized Ic / Part
CS8900A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Other names
598-1163
RegNum
RegContent
Reset value is: 0000 0000 0000 0000
4.4.6 Register 3: Receiver Configuration
(RxCFG, Read/Write, Address: PacketPage base + 0102h)
RxCFG determines how frames will be transferred to the host and what frame types will cause interrupts.
000011
Skip_1
StreamE
RxOKiE
RxDMAonly
AutoRxDMAE
BufferCRC
CRCerroriE
RuntiE
ExtradataiE
After reset, if no EEPROM is found by the CS8900A, then the register has the following initial state. If an EEPROM
is found, then the register’s initial value may be set by the EEPROM. See Section 3.3 on page 19.
Reset value is: 0000 0000 0000 0011
54
StreamE
7
F
ExtradataiE
Skip_1
The lower six bits describe which register (4, 8, C, 10 or 12) is contained in the ISQ.
The upper ten bits contain the register data contents.
Configuration Register.
fer. To skip another frame, the host must rewrite a “1” to this bit. This bit is not to be used if
RxDMAonly (Bit 9) is set. Skip_1 is an Act-Once bit. See Section 5.2.5 on page 85.
that pass the Destination Address filter (see Section 5.2.10 on page 87). When StreamE is
clear, StreamTransfer mode is not used. This bit must not be set unless either bit AutoRxDMA
or bit RXDMAonly is set.
not generated when DMA mode is used for frame reception.
ified in Section 5.4 on page 94 are met. RxDMAonly (Bit 9) has precedence over AutoRxD-
MAE.
the four CRC bytes are included in the receive-frame length (PacketPage base + 0402h). When
clear, neither the receive buffer nor the receive length include the CRC.
CS8900A always discards any frame that is shorter than 8 bytes.
The operation of this bit is independent of the received packet integrity (good or bad CRC).
These bits provide an internal address used by the CS8900A to identify this as the Receiver
When set, this bit causes the last committed received frame to be deleted from the receive buf-
When set, StreamTransfer mode is used to transfer receive frames that are back-to-back and
When set, there is an RxOK Interrupt if a frame is received without errors. RxOK interrupt is
The Receive-DMA mode is used for all receive frames when this bit is set.
When set, the CS8900A will automatically switch to Receive-DMA mode if the conditions spec-
When set, the received CRC is included with the data stored in the receive-frame buffer, and
When set, there is a CRCerror Interrupt if a frame is received with a bad CRC.
When set, there is a Runt Interrupt if a frame is received that is shorter than 64 bytes. The
When set, there is an Extradata Interrupt if a frame is received that is longer than 1518 bytes.
E
6
RuntiE
D
5
CIRRUS LOGIC PRODUCT DATASHEET
CRCerroriE
C
4
BufferCRC
B
3
000011
AutoRx DMAE RxDMA only
Crystal LAN™ Ethernet Controller
A
2
1
9
CS8900A
RxOKiE
DS271F5
0
8

Related parts for CRD8900A-1