CDB4271 Cirrus Logic Inc, CDB4271 Datasheet - Page 14

EVAL BOARD CS4271 STEREO CODEC

CDB4271

Manufacturer Part Number
CDB4271
Description
EVAL BOARD CS4271 STEREO CODEC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CDB4271

Main Purpose
Audio, CODEC
Embedded
Yes, FPGA / CPLD
Utilized Ic / Part
CS4271
Primary Attributes
Stereo, 24-Bit, 192 kHz Sample Rate
Secondary Attributes
I²S, S/PDIF Inputs and Outputs, Analog Inputs and Outputs, GUI
Product
Audio Modules
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1003
14
3.2
3.3
Clicking the “Advanced...” button on the main window will launch a graphical register map of
the CS4271. Changes made to the register map will be immediately reflected in the main win-
dow, so you may wish to arrange them so that they do not obscure each other. When in I
mode, the “Update” button will read the registers of the CS4271 and update the Advanced
Register Settings box to match. See Figure 3 below.
The control port of the CS4271 requires the presence of an MCLK signal for correct opera-
tion. Because of this, if the board is set up to receive MCLK from a source that isn’t actively
providing the signal, a no acknowledge error may result. This means that the GUI is expecting
an acknowledgement from the CS4271, but isn’t receiving it. If this occurs, ensure that the
appropriate source of MCLK is providing the signal. For example, if the board is set up to re-
ceive MCLK from the header, be sure that there is an active MCLK signal applied to the
MCLK position on the header (J26). See Figure 4 below.
Advanced Window
I²C Mode No Acknowledge Error
Figure 3. Advanced Window
Figure 4. I²C Error Message
CDB4271
2
C