S82S-7712 Omron, S82S-7712 Datasheet - Page 3

POWER SUPPLY SWITCHING 12V 0.6A

S82S-7712

Manufacturer Part Number
S82S-7712
Description
POWER SUPPLY SWITCHING 12V 0.6A
Manufacturer
Omron
Series
S82Sr
Datasheets

Specifications of S82S-7712

Input Voltage
12 V to 24 V
Output
12V
Number Of Outputs
1
Power (watts)
7W
Mounting Type
DIN Rail
Voltage - Input
12 ~ 24V
Package / Case
Module
1st Output
12 VDC @ 600mA
Size / Dimension
2.56" L x 1.48" W x 2.95" H (65mm x 37.5mm x 75mm)
Power (watts) - Rated
7.5W
Approvals
CE, CSA, UL, VDE
Product
Switching
Commercial/medical
Both
Output Power Rating
7.5 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
0.6 A
Mounting Style
DIN Rail
Dimensions
65 mm L x 75 mm W x 37.5 mm H
Open Frame/enclosed
Enclosed
Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Power Rating
7.5W
Output Voltage
12VDC
Output Current
0.6A
Approval Bodies
CSA, UL
Supply Voltage
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82S7712
Engineering Data
J DERATING CURVE
Note: The derating curve depends on the mounting position
Nomenclature
4
5
Mounting Position
(A): Standard (Vertical)
3
Installation
of the power supply.
Top
Switching Power Supply
2
Ambient temperature (_C)
S82S-7724
POWER SUPPLY
6
(B)
1
3
(B): Horizontal
(A)
4
Installation
Top
S82S
1
2
S82S-7727
POWER SUPPLY
3
1
Output
voltage (V)
J OVERLOAD PROTECTION
The power supply is provided with an overload protection
function that protects the load and the power supply from
possible damage by overcurrent. When the output current
rises above a set value (105% of the rated output current),
the protection function is triggered, decreasing the output
voltage. When the output current falls within the rated range,
the overload protection function is automatically cleared.
1. DC Output Terminals: Connect load wiring.
2. Input Terminals: Connect input wiring.
3. Ground Terminals: Connect ground wiring.
4. Output LED Indicator: Lights when DC current is being
5. V. ADJ Adjuster: Use to adjust the output voltage.
6. NC Terminals: Vacant terminals.
output.