DLPPU/E TDK Corporation, DLPPU/E Datasheet

PWR SUP DIN RAIL 21-28VDC 20A

DLPPU/E

Manufacturer Part Number
DLPPU/E
Description
PWR SUP DIN RAIL 21-28VDC 20A
Manufacturer
TDK Corporation
Series
DLP-PUr
Type
Isolatedr
Datasheet

Specifications of DLPPU/E

Output
0 ~ 28V
Number Of Outputs
1
Power (watts)
240W
Mounting Type
DIN Rail
Voltage - Input
21 ~ 28V
Package / Case
Module
1st Output
0 ~ 28 VDC @ 20A
Size / Dimension
4.33" L x 1.97" W x 3.81" H (110mm x 50mm x 97mm)
Power (watts) - Rated
240W
Operating Temperature
-10°C ~ 70°C
Approvals
CE, CSA, EN, TUV, UL
Power Supply Type
Power Module
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
28V
Output Current
20A
Power Rating
240W
Input Voltage
21V DC To 28V DC
Length
110mm
Width
50mm
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Din-Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Compliant
Other names
285-1211
DLP-PU/E
Note:
F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Input Voltage Range
Number of inputs
Maximum Input Current
Maximum Output Current
Overcurrent protection
Voltage Drop
Maximum Reverse Voltage
LED Indicators
Input Voltage Alarm
Relay contact rating (max)
Cooling
Operating Temperature
Storage Temperature
Humidity
Withstand Voltage
Isolation Resistance
Vibration
Shock
Safety Agency Approval
Size
Weight
Warranty
See Installation Manual for full details, test methods of parameters and application notes
Internal ORing Diodes
Can connect two units in parallel
Output voltage monitoring (via relays)
DIN Rail Mounting
MODELS
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm/in
VDC
VDC
VDC
yrs
A
A
g
-
-
-
-
-
-
-
-
-
-
-
-
-
UL60950-1, CSA60950-1, EN60950-1, UL508, CSA22.2 No.14, EN60529 IP20, EN50178 Cat 1
Power Supply Parallel or Redundancy Module
DLP-PU Series
Relay off when input is <19.2V (±1%) or > 30V (±5%). NO and NC contacts
Relay Contacts to Chassis; >10M Ohms at 25°C, 70%RH and 500VDC
Non operating, mounted on DIN Rail,10-55Hz (sweep for 1 min),
Operating: 30 - 90%RH, Storage: 10 - 95%RH (non condensing)
28VDC, 1A or 120VAC, 0.5A (5mA minimum recommended)
Input or Output - Chassis, Input or Output - Relay Contacts,
Input or Output - Chassis, Input or Output - Relay Contacts,
-10 to +70°C, derate linearly to 60% from 60 to 70°C
Two green LEDs indicating each input is "good"
Relay Contacts to Chassis; 500VAC for 1 min.
9.8m/s
50 x 97 x 110mm, 1.97x 3.81 x 4.33"
Benefit
OR-ing Diodes Included
Alarm Signals
LED Indicators
DIN Rail Mounting
2
Allows redundant operating
Enables system scalability
Remote alarm notification
Easier system integration
constant X, Y, Z each for 1 hour
20A per input
-30 to +90°C
21 - 28VDC
Three Years
Convection
DLP-PU/E
196m/s
35VDC
None
470g
0.5V
20A
Two
2
23

Related parts for DLPPU/E

DLPPU/E Summary of contents

Page 1

Feature Internal ORing Diodes Can connect two units in parallel Output voltage monitoring (via relays) DIN Rail Mounting ...