S82Y-J10F Omron, S82Y-J10F Datasheet - Page 4

no-image

S82Y-J10F

Manufacturer Part Number
S82Y-J10F
Description
MOUNTNG BRAKT FRONT FOR S82J-100
Manufacturer
Omron
Series
S82Jr
Datasheets

Specifications of S82Y-J10F

Accessory Type
Mounting Bracket(s)
For Use With/related Products
S82J 100W Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S82YJ10F
Specifications
■ Ratings/Characteristics
Efficiency (typical)
Input
Output
(See
note 4.)
Addi-
tional
tions
Other
func-
Voltage (See note 2.)
Frequency (See note 2.)
Current
(See note 3.)
Leakage current
(See note 3.)
Inrush current
(See note 3.)
Noise filter
Voltage Adjustment Range
(See note 5.)
Ripple (See note 3.)
Input variation influence
Load variation influence
Temperature variation influence 0.05%/°C max. (at rated input and output)
Startup time
Hold time (See note 3.)
Overload protection
(See note 6.)
Overvoltage protection
Overheat protection
Parallel operation
Protection-ON alarm indicator
Ambient operating temperature Refer to the derating curve in Engineering Data. (with no icing or condensation)
Storage temperature
Ambient operating humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved standards
Weight (See note 10.)
Power ratings
(See note 1.)
100-V input
200-V input
100-V input
200-V input
100-V input
200-V input
Conducted
Emissions
(See note 3.)
Radiated
Emissions
67% min. (Varies depending on
specifications)
100 to 240 VAC (85 to 264 VAC)
110 to 170 VDC (10-W and 25-W models only) (See
note 11.)
50/60 Hz (47 to 450 Hz)
0.35 A max. 0.8 max.
0.3 A max.
0.5 mA max.
1 mA max.
25 A max. (for a cold start at 25°)
50 A max. (for a cold start at 25°)
Yes
±10% (with V. ADJ)
2% (p-p) max.
0.4% max.
0.8% max. (10% to 100% load, rated input voltage)
500 ms max. (up to 90% of output voltage at rated input and output)
20 ms min.
105% to 160% of rated load current, voltage/current drop, intermittent operation
(10-W and 25-W models) gradual current increase/ voltage drop, intermittent
operation (50-W, 100-W (24 V) models), automatic reset
No
No
No
No
−25 to 65°C (with no icing or condensation)
25% to 85% (Storage humidity: 25% to 90%)
3.0 k VAC for 1 min. (between all inputs and all outputs)
2.2 k VAC for 1 min. (between all inputs and all outputs/PE terminals)
1.0 k VAC for 1 min. (between all outputs and PE terminal)
100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2h each in X, Y, and Z directions
300m/s
Yes (color: green)
Conforms to EN61204-3 EN55011 Class A and based on FCC Class A
Conforms to EN61204-3 EN55011 Class A (See note 9.)
Conforms to EN61204-3 Low severity levels
UL: UL508 (Listing; Class 2: Per UL1310
cUL: CSA C22.2 No.14 (Class 2 approved for
cUR: CSA No. 60950-1
EN/VDE: EN50178 (=VDE0160)
Terminal types (only terminal part):
Based on VE0106/P100
250 g max.
10 W
Class 2 approved for 10-W, 25-W (except
for 5-V output)), and 50-W (only for 24-V
output) models.), UL60950-1
10-W, 25-W (except for 5-V output), and
50-W (only for 24-V output) models.)
2
, 3 times each in ±X, ±Y, ±Z directions
0.6 A max.
350 g max.
100 to 240 V (Free)
25 W
VDE0106/P100
1.4 A max.
0.8 A max.
400 g max.
50 W
83% min.
2.5 A max. 2.5 A max.
1.5 A max. 1.4 A max.
Yes (See
note 7.)
Models with Terminals
UL: UL508 (Listing), UL1012, UL60950-1
cUL: CSA C22.2 No. 14 (Listing)
cUR: CSA No. 60950-1
EN/VDE: EN50178 (=VDE0160)
Terminal types (only terminal part):
Based on VE0106/P100
Models with Connectors
UL: UL508, UL1012, UL60950-1
CSA: CSA C22.2 No.14
EN/VDE: EN50178 (=VDE0160)
500 g max. 1,000 g max.
100 W
(24 V)
CSA No. 60950-1
75% min.
100 VAC (85 to 132 VAC)
200 VAC (170 to 264 VAC)
(selected automatically)
Yes (5-V
output only)
(See note 7.)
100 W (5 V,
12 V, 15 V)
100/200 (Selected
automatically)
VDE0106/P100
3.5 A max.
2.1 A max.
82% min.
No
150 W
100 VAC (85 to 132 VAC)
200 VAC (170 to 253 VAC)
(selectable)
8 A max.
4 A max.
voltage at rated input and output)
105% of rated load current, Inverted L
voltage drop, automatic reset (For the
600-W model, the circuit will be shut
OFF when the overload exceeds 5 s.)
Yes (See note 8.)
Yes (up to 5 units)
Yes (color: red)
UL:
CSA: EB1402C, C22.2 No. 14
EN/VDE: EN50178 (=VDE0160)
Terminal types (only terminal part):
Based on VE0106/P100
2,000 g max.
300 ms max. (up to 90% of output
UL508, UL1012
300 W
100/200 (Selected)
14 A max.
7 A max.
30 A max. (for a cold
start at 25°)
60 A max. (for a cold
start at 25°)
Yes (See note 8.)
2,500 g max.
VDE0106/P100
600 W
S82J
4

Related parts for S82Y-J10F