S82Y-H05B Omron, S82Y-H05B Datasheet - Page 5

no-image

S82Y-H05B

Manufacturer Part Number
S82Y-H05B
Description
MOUNTNG BRAKT BOTTOM FOR S82H-50
Manufacturer
Omron
Series
S82Hr
Datasheets

Specifications of S82Y-H05B

Accessory Type
Mounting Bracket(s)
For Use With/related Products
S82H-35xx Power Supply
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S82YH05B
Specifications Table
Note: 1. The fan is one of the replacement parts (300- and 600-W models).
Power ratings
Additional functions
Overload protection
Overvoltage protection
Parallel operation
Series operation
Remote sensing
Remote control
Remote voltage adjustment
Cooling method
Fan alarm function
Characteristics
Ambient
Ambient
temperature
temperature
Ambient operating humidity
Dielectric strength
Insulation resistance
Vibration
resistance
Shock
resistance
Output indicator
EMC
Limits for harmonic current
emission
EMC standards
Electromagnetic interference
Approved standards
Weight
2. As defined with the rated input voltage and rated output voltage/current.
3. A surge absorber is provided for the input circuits. To test the dielectric strength and insulation resistance of these models,
4. To ensure emission enclosure rating, ferrite cores should be used on all cabling.
remove the short bar attached across the GR and ACG terminals.
Operating
Storage
Malfunction
Malfunction
– continued from previous page
100 W
105% max. of rated load current, inverted L drop type, automatic reset
120% of rated output voltage (typical), shutoff type, input reset
No
Yes
Yes
No
Yes
Natural air-cooling used
No
See the derating curve in the Engineering Data section. (No condensation or icing.)
–25°C to 65°C (–13°F to 149°F) with no condensation or icing
25% to 85%
3 kVAC, 50/60 Hz for 1 min between all inputs and all outputs with a current leakage of 25 mA max.
2.5 kVAC, 50/60 Hz for 1 min between all inputs and GR terminals with a current leakage of 25 mA
max.
1.0 kVAC, 50/50 Hz for 1 min between all outputs and GR terminals with a current leakage of 15 mA
max. for each 100-W model, 20 mA max. for each 150-W model.
100 MΩ min. between all outputs and all inputs/GR terminals at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 hrs each in X, Y, and Z directions
300 m/s
Yes (green)
Emission Enclosure (See Note 4.): EN55022 Group 1 class B
Emission AC Mains:
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: ENV50141:10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
---
Conforms to EN50081-1, EN50082-2
Conforms to FCC class B, EN50081–1
UL1012, CSA E.B. 1402C, VDE 0160, IEC 950, EN 60950, CE
950 g
max.
2
(approx. 30G), 3 times each in ±X, ±Y, and ±Z directions
150 W
Yes, up to five units
Yes
1,800 g max.
EN55022 Group 1 class B
EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge
(level 3)
ENV50140:10 V/m (10 k to 1 GHz) (level 3)
EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line
(level 4)
Switching Power Supply
S82H
5

Related parts for S82Y-H05B