D1U-48-CONC Murata Power Solutions Inc, D1U-48-CONC Datasheet
D1U-48-CONC
Specifications of D1U-48-CONC
Related parts for D1U-48-CONC
D1U-48-CONC Summary of contents
Page 1
... Status information is provided with front panel LEDs, logic signals and I can be packaged into an optional 19” 1U power shelf to provide up to 3.6kW of power. The S1U- 19” EIA Rack Mount Power Shelf designed for holding three D1U Front End Power Supplies in current sharing applications intended for distributed power architecture applications in the Servers, Storage Networking and Data Communications markets ...
Page 2
... A 1530 μF 5 Vdc 5. p 1530 μF 12 Vdc 12.4 120 mV p-p 0 1.7 A 1530 μF Typ. Max. Units 240 mV 90.6 % 1.5 s 150 ms ±2700 ±165 mV ±250 ±600 ± Typ. Max. Units 70 ° Khrs Khrs 60 dB LpAm email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-1200-48-Hx.C08 Page ...
Page 3
... A Typ. Max. Units Vrms Vrms Criteria Class A, 6dB margin Class A, 6dB margin 4kV contact discharge 8kV operational air discharge 15kV non-operational air discharge 1kV/2kV, Performance Criteria B 3 Vac, 80% AM, 1kHz, Performance Criteria A 3 A/m email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-1200-48-Hx.C08 Page ...
Page 4
... Vsb) N/A <0.7V (active, PS:On >2.1V (open, or Vsb <0.7V (active, PS:On Vsb Vsb >2.1V, < Vsb ±1 mA <0.8V >2.1V, <Vsb ±1 mA <0.8V >2.1V, <Vsb ±1 mA <0.8V Solder 2 Straight Right Angle 36-0440026-0 51762-10602000ABLF TBD email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-1200-48-Hx.C08 Page ...
Page 5
... Vsb < 0.7V (active, PS:On > 2.1V, < Vsb ± < 0.8V Vsb Vsb High Level I Max Low Level open drain - 2 mA < 0. open drain - < 0.7V > 2.1V (open, or Vsb < 0.7V (active, PS:On Vsb Vsb email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-1200-48-Hx.C08 Page ...
Page 6
... AWG#2 wire, Panduit lug LCC2-14AWF-Q or equivalent is recommended. 2. Two M6 studs at 15.88 mm centre spacing are provided for connection to each pole. Hardware is provided for fastening the lugs/wires as well as terminal block covers 08 Apr 2010 CPS_D1U-W-1200-48-Hx.C08 Page 37,31 ±0,40 [ 1.469 ±0.015 ] 132,85 ± ...
Page 7
... FOR SHELF-TO-SHELF CONNECTION USE CABLE P/N 535-413-1537-1 J1 SIGNAL CONNECTOR TO CUSTOMER SYSTEM Part Number D1U-48-CONC 535-413-1537 Description D1U Communication Protocol Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi ...