GLM75IG SL Power Electronics Manufacture of Condor/Ault Brands, GLM75IG Datasheet - Page 2

no-image

GLM75IG

Manufacturer Part Number
GLM75IG
Description
PWR SPLY MED SWITCHER 75W MULTI
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLM75r
Datasheet

Specifications of GLM75IG

Power (watts)
75W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Mounting Type
Chassis Mount
Size / Dimension
7" L x 4.25" W x 1.3" H (177.8mm x 108mm x 33mm)
Power (watts) - Rated
75W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, CSA, EN, IEC, UL
Line Regulation
2%; 10%, -5%; 3%
Load Regulation
2%; 10%, -5%; 3%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Output
-
Voltage - Input
-
Number Of Outputs
-
1st Output
-
3rd Output
-
2nd Output
-
4th Output
-
Other names
271-2543
* Add “G” suffix to part number for RoHS compliant model. Contact factory for availability.
A. Rating with unrestricted convection cooling. Total power not to exceed 75 W.
B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W.
C. Floating fourth output can be referenced as either positive or negative. Connect pin 12 to Return to provide a positive voltage at Pin 13. Connect pin 13 to Return to
provide a negative voltage at Pin 12.
D. To maintain these regulations conditions, the +5V current must be at least 1/5 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted to within
1% with at least a 1 A load to maintain regulation on this output.
SL Power Electronics, Inc., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 9-23-10.
Data Sheet © 2010 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
GLC75/GLM75 - MULTIPLE OUTPUT - MECHANICAL SPECIFICATIONS
Commercial
Model
GLC75A
GLC75B
GLC75C
GLC75D
GLC75E
GLC75F
GLC75H
GLC75J
GLC75P
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Medical
Model
GLM75A
GLM75B
GLM75C
GLM75D
GLM75E
GLM75F
GLM75H
GLM75J
GLM75P
Suffix*
RoHS
G
G
G
G
G
G
G
G
G
Output
No.
4(C)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
1
2
3
4
OPERATING
0 to 50°
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
rms’
0.003 g
Output
+5.1 V
+12 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+5.1 V
+12 V
+12 V
+12 V
+12 V
+15 V
+24 V
+12 V
+24 V
+15 V
+15 V
+15 V
+15 V
+12 V
+24 V
+12 V
-12 V
-15 V
-12 V
-15 V
-15 V
-15 V
-12 V
-12 V
-5 V
-5 V
5 V
2
/Hz
Minimum
Output
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0 A
0 A
1 A
0 A
0 A
1 A
0 A
0 A
1 A
0 A
0 A
1 A
0 A
0 A
1 A
1 A
1 A
0 A
0 A
1 A
1A
0
0
0
0
0
0
rms’
pk
0.026 g
Maximum (A)
2
/Hz
Output
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
2.0 A
2.5 A
8 A
1 A
8 A
1 A
8 A
1 A
8 A
1 A
8 A
1 A
8 A
1 A
8 A
1 A
8 A
1 A
8 A
4 A
1 A
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
output power by 2.5% per °C above 50°C.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
Maximum (B)
Output
2.5 A
2.5 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
3 A
1 A
3 A
3 A
1 A
3 A
3 A
1 A
3 A
1 A
3 A
1 A
3 A
3 A
1 A
3 A
3 A
1 A
3 A
3 A
1 A
3 A
4 A
1 A
3 A
Output
Peak
1.2 A
1.2 A
1.2 A
3.5 A
1.2 A
3.5 A
1.2 A
1.2 A
1.2 A
1.2 A
4.5 A
1.2 A
12 A
12 A
12 A
12 A
12 A
12 A
12 A
12 A
12 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
4 A
V1 OVP Set
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
Noise P-P
120 mV
120 mV
120 mV
120 mV
120 mV
120 mV
150 mV
150 mV
120 mV
120 mV
240 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
120 mV
120 mV
120 mV
120 mV
240 mv
240 mv
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
+10%,-5% (D)
Regulation
2%
3%
2%
2%
3%
2%
2%
3%
2%
2%
3%
2%
2%
3%
2%
2%
3%
2%
2%
3%
2%
2%
3%
2%
2%
3%
2%

Related parts for GLM75IG