HSD-24-4.8 TDK Corporation, HSD-24-4.8 Datasheet - Page 2

no-image

HSD-24-4.8

Manufacturer Part Number
HSD-24-4.8
Description
PWR SUP 24V 115.2W 4.8A SNG OUT
Manufacturer
TDK Corporation
Series
Hr
Datasheets

Specifications of HSD-24-4.8

Number Of Outputs
1
Efficiency
60%
Voltage - Output
24V
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100, 120, 220, 230, 240VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 4.8A
Size / Dimension
8.82" L x 4.88" W x 2.76" H (224mm x 124mm x 70mm)
Power (watts) - Rated
100W
Operating Temperature
0°C ~ 70°C
Approvals
CE, EN, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Output Current (max)
4.8A
Output Voltage
24V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
85mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
HSD244.8
HSD244.8
7) AC fuse
8) External Overvoltage Protectors (OVP12 module)
Apply L & N to:
For use at:
Jumper(s)
An external fuse (see ratings table) should be installed. Use a 125VAC or higher
rated fuse for 100-120VAC operation, and a 250VAC fuse for 220-240VAC
operation. Fuse type should be anti-surge.
In general most 5V output H Series power supplies come with internal Over Voltage
Protection. If OVP is required on other voltage outputs, then an external OVP
module should be fitted as follows:
The OVP module is user adjustable from approximately 6.2V to 34V.
The maximum current rating of the OVP12 module is 12A peak, 8A continuous.
The recommended trigger voltages are
The above table indicates Lambda’s recommended level set point for different output
voltages. Where +/- outputs exist with a common terminal, a single OVP module
located across the + and – terminals will provide functional OVP for both individual
outputs.
The OVP module comes complete with mounting hardware and hookup leads. To
connect the OVP to your supply, see your power supply’s user’s manual for
recommended placement or Lambda’s website
supply outline drawing. See example below
Nominal Output Voltage
1 - 3, 2 - 4
100VAC
AC INPUT & JUMPER INFORMATION
1 - 5
Dual +/-12V
Dual +/-15V
12V
15V
24V
5V
LAMBDA
1 – 3, 2 - 4
120VAC
1 – 4
HSeries
Suggested Trip Point
www.lambda.com
6.2 +/-0.4V
220VAC
14V
17V
27V
27V
33V
2 - 3
1 - 5
for the power
230/240VAC
2 - 3
1 - 4

Related parts for HSD-24-4.8