POWER SUPPLY 30W 3OUT OPEN

S8E3-03031A

Manufacturer Part Number
S8E3-03031A
Description
POWER SUPPLY 30W 3OUT OPEN
Manufacturer
Omron
Series
S8E3r
Datasheet

Specifications of S8E3-03031A

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
30W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 132VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
12 VDC @ 1.2A
3rd Output
-12 VDC @ 300mA
Size / Dimension
6.77" L x 2.71" W x 1.3" H (172mm x 69mm x 33mm)
Power (watts) - Rated
30W
Operating Temperature
-10°C ~ 60°C
Efficiency
73%
Approvals
CSA, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
4th Output
-
Other names
S8E303031A
Z1159
Note: 1. The overload protection function of output V
J OVERLOAD PROTECTION
The S8E3 is provided with an overload protection function
that protects the load and the S8E3 from possible damage
by overcurrent. The following graph shows the overload
detection and reset operation of the S8E3.
AC input
voltage
AC input
current
Output
voltage
J OVERVOLTAGE PROTECTION
The Power Supply is provided with an overvoltage protection
function that protects the load and the Power Supply from
possible damage by overvoltage. When the output voltage
rises above a set value (120% of the rated output voltage),
the protection function is triggered, shutting off all of the
output voltage. If this occurs, reset the Power Supply by
turning it off for 1 minute min. and then turning it on again.
J INRUSH CURRENT, START UP TIME, HOLD TIME
Type
V1
V2, V3
(V1 OUTPUT ONLY)
2. V2 and V3 have an independent short-circuit protection function.
3. Do not continue operating the S8E3 if an output terminal is short-circuited or overloaded, or the S8E3 may incur output voltage
Input ON
put capacity of the S8E3 (total overcurrent protection). If outputs V
for V
eration depends on the output status of outputs V
fluctuation, internal element deterioration, or damage.
Operating method
Inverted drop
Short-circuit protection
Inrush current on input application
1
operates with its output current is 105% or more of the rated output current. Caution is required, however, because op-
Start up time
(100 ms max.)
Detection
105% min. of rated
load current
---
90%
1
is triggered when the total output of V
2
Input OFF
and V
Hold time
(20 ms min.)
Reset
Automatically resets
when the output current
returns to normal
Automatically resets
when the output current
returns to normal
3
96.5%
.
2
and V
Switching Power Supply
3
are within their rated currents, overload protection
Rated output
voltage
Approx.
20%
5%
1
, V
Output current (%)
2
, and V
Rated voltage
Variable range
3
exceeds the permissible out-
S8E3
Rated voltage
Overvoltage
protection
operating
4

Related parts for S8E3-03031A