2866255 Phoenix Contact, 2866255 Datasheet - Page 3

PWR SUPPLY 5A 100-240AC 48VDC

2866255

Manufacturer Part Number
2866255
Description
PWR SUPPLY 5A 100-240AC 48VDC
Manufacturer
Phoenix Contact
Series
Quintr
Type
Industrialr
Datasheets

Specifications of 2866255

Voltage - Output
48V
Number Of Outputs
1
Power (watts)
240W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
48 VDC @ 5A
Size / Dimension
4.92" L x 3.35" W x 5.12" H (125mm x 85mm x 130mm)
Power (watts) - Rated
240W
Operating Temperature
-25°C ~ 70°C
Efficiency
91%
Approvals
CB, cUL, UL
Product
Switching
Commercial/medical
Commercial
Output Power Rating
240 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
48 VDC
Output Current (channel 1)
5 A
Mounting Style
DIN Rail
Brand/series
QUINT-PS
Configuration
Enclosed
Current, Inrush
15 A (Typ.) Approximately
Current, Rating
2.2 A (For 120 VAC)⁄1.2 A (For 230 VAC)
Frequency
45 to 65 Hz
Height
5.118 in.
Operation
Switching
Output
48 VDC @ 5 A
Phoenix Part Number
QUINT-PS-100-240AC/48DC/5
Power, Output
24 W
Primary Type
AC-DC
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-25 °C
Voltage, Input
85 to 264/90 to 350 VAC/VDC
Voltage, Output
48 VDC
Voltage, Rating
100 to 240 VAC (Nom.) Input
Width
3.346 in.
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
277-1866
2866255
Q2481297
QUINT-PS-100-240AC/48DC/5
QUINT-PS-100-240AC/48DC/ 5
PHOENIX CONTACT Inc., USA
Class of protection
MTBF
Ambient temperature (operation)
Ambient temperature (storage/transport)
Max. permissible relative humidity (operation)
Mounting position
Assembly instructions
Electromagnetic compatibility
Emitted interference
Immunity to interference
Standard – Safety transformers for switched-mode
power supply units
Standard - Electrical safety
Standard – Shipbuilding
Standard – Electronic equipment for use in
electrical power installations and their assembly
into electrical power installations
Standard - Safe isolation
Standard – Limitation of mains harmonic currents
Standard – Equipment safety
Certificate
UL approvals
Connection data, input
Type of connection
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section AWG/kcmil min.
Conductor cross section AWG/kcmil max
Stripping length
Screw thread
Order No.: 2866255
I, with PE connection
> 500 000 h in acc. with IEC 61709 (SN 29500)
-25 °C ... 70 °C (> 60°C derating)
-40 °C ... 85 °C
95 % (at 25°C, no condensation)
Horizontal DIN rail NS 35, EN 60715
Can be aligned: Horizontal 0 cm, vertical 5 cm
Conformance with EMC directive 89/336/EEC
EN 50081-2
EN 61000-6-2
EN 61558-2-17
EN 60950/VDE 0805 (SELV)
EN 61558-2-17
German Lloyd, ABS
EN 50178/VDE 0160 (PELV)
DIN VDE 0100-410
DIN VDE 0106-1010
EN 61000-3-2
GS (tested safety)
CB Scheme
UL/C-UL Recognized UL 60950
UL/C-UL listed UL 508
Pluggable screw connection
0.2 mm²
2.5 mm²
0.2 mm²
2.5 mm²
24
12
7 mm
M3
Page 3 / 6

Related parts for 2866255