DMP1-12025 Acme Electric/Amveco/Actown, DMP1-12025 Datasheet

PWR SPLY 30W 3A 12VDC DIN-RAIL

DMP1-12025

Manufacturer Part Number
DMP1-12025
Description
PWR SPLY 30W 3A 12VDC DIN-RAIL
Manufacturer
Acme Electric/Amveco/Actown
Series
DMr
Datasheets

Specifications of DMP1-12025

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
30W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
DIN Rail
1st Output
12 VDC @ 3A
Size / Dimension
4.02" L x 0.9" W x 3.54" H (102mm x 22.8mm x 90mm)
Power (watts) - Rated
30W
Operating Temperature
-10°C ~ 50°C
Efficiency
84%
Approvals
CE, UL
Line Regulation
±0.5%
Load Regulation
±1%
Lead Free Status / RoHS Status
Lead free by exemption / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
WARNING: Never work on the power supply when power is applied. Electric shock and arc risks can cause death, severe personal
injury or substantial property damage. Power source must be off and properly secured before any installation, maintenance or modification
work is completed. Keep away from fire and water. Before installing unit, thoroughly read these instructions.
1. As a reminder, these products are not to be installed in nuclear or medical (patient connect) applications.
2. The units meet the safety requirements of UL508, UL60950-1, IEC/EN60950. They are approved in accordance with EN60950, UL508,
3. These units must always be installed with any national, county or city regulations that apply. Connections to mains supply must be in
4. Sufficient temperature and cooling and space clearances must be ensured as indicated: Operation requires no external cooling but
5. Avoid potential danger of contact with case by ensuring all strands of stranded wire use (if applicable) are fastened in the terminal blocks.
6.
7.
8. Do not introduce any objects into the power supply. The output voltage adjustment potentiometer may only be actuated using
1. Read and follow all instructions before installation as indicated in this manual. This publication is based on information that was
2. DIN Rail Connection; as per local electrical codes and recommended wire sizes.
3. DIN Rail mounted per VDE0160 Please see diagram as noted below.
4. This power supply is designed for professional indoor systems. During operation the power supply must not be accessible. Install and put
5. Do not operate without Protective Earth (PE) connection! To comply with EMC and safety standards (CE mark, approvals) the power
6. Do not cover any ventilation holes. The correct mounting position for optimal cooling performance must be observed. All free space
7.
8. Please ensure that the power supply will be recycled properly at the end of its life. Some components of this power supply may be
WARNING The internal fire safety fuse is not accessible. This fuse is not to be replaced by the user. For continued protection
Safety Instructions
SAFETY ALERT Hazardous voltages and components storing a substantial amount of energy are present in this unit during normal
WARNING Do not open the power supply until at least 5 minutes after it has been disconnected from the mains on all poles.
professionals. Only professionally trained personnel may open the power supply. If you have any questions concerning the
installation or operation of this equipment, please call the number located at the front of this document.
(TUV) EN55022, EN55024, CE MARKING and meet the requirements EMC and the Low Voltage Directive.
compliance with national and city regulations. Power supply and main cables must be sufficiently fused in accordance with local codes.
Follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary, and it is
your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in
compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result by not following all
applicable standards and codes.
application, nor do we assume any responsibility for your product design, installation, or operation.
requires minimum clearances on top, bottom, and sides of units. Refer to installation Cooling and Airflow Requirements below
operating conditions.
an insulated screwdriver.
available at the time it was printed. We reserve the right to make changes to the products and/or publications at any time without notice
and without obligation.
into service by qualified personnel only.
supply must be operated only if PE terminal is connected to the non-fused earth conductor.
requirements and power de-rating as specified at the beginning of this manual must be observed.
against risk of fire, NO REPLACEMENT OF FUSE IS ALLOWED REGARDLESS. If this internal fuse has blown, the power supply has
a serious internal defect, and for safety reasons, must be discarded, or if under warranty, returned.
suitable for recycling, including some that require special disposal.
Installation Instructions
NOTICE: Products are not to be used nor are warranted in aerospace, nuclear, medical patient connect, or lifesafety applications.
SAFETY ALERT
This manual is subject to change without prior notice.
FOR YOUR SAFETY, READ ALL INSTRUCTIONS BEFORE INSTALLATION AND OPERATION.
Improper handling may result in electric shock or serious burns.
WARNING – Avoid Possible Injury or Death
We do not guarantee the products described in this publication are suitable for your particular
DIN Rail Power Supplies, Plastic Single Phase
WARNING – Avoid Personal Injury or Product Damage.
INSTALLATION MANUAL
Units are only to be installed by

Related parts for DMP1-12025

DMP1-12025 Summary of contents

Page 1

SAFETY ALERT FOR YOUR SAFETY, READ ALL INSTRUCTIONS BEFORE INSTALLATION AND OPERATION. NOTICE: Products are not to be used nor are warranted in aerospace, nuclear, medical patient connect, or lifesafety applications. This manual is subject to change without prior notice. ...

Page 2

Cooling and Airflow 1. Airflow must be upward as shown in figure. 2. Always maintain operation conditions within output power and temperature ratings. 3. All units are rated for convectional cooling but require that there is at least 25mm both ...