MVA100024A ICC/Elpac Power Syst, MVA100024A Datasheet

POWER SUP MEDICAL 100W 24V 4.2A

MVA100024A

Manufacturer Part Number
MVA100024A
Description
POWER SUP MEDICAL 100W 24V 4.2A
Manufacturer
ICC/Elpac Power Syst
Series
MVA100r
Datasheet

Specifications of MVA100024A

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
100W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 4.2A
Size / Dimension
4.5" L x 2.5" W x 1.1" H (114.3mm x 63.1mm x 28.5mm)
Power (watts) - Rated
100W
Operating Temperature
0°C ~ 40°C
Efficiency
91%
Approvals
CB, CE, CSA, cTUVus, UL
Line Regulation
±5%
Load Regulation
±5%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
EPS423
A
1-888-357-2280
saleselpac@iccus.com
www.iccus.com
+44.1383.432920
saleseurope@iccus.com
TECHNICAL SUPPOrT
WOrLDWIDE
EUrOPE
Notes
**Ripple and noise measured with 20MHz bandwidth; 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor.
Input Voltage
Input Frequency
Input Current
Inrush Current
Zero Load
Power Consumption
Touch Current /
Leakage Current
Patient
Leakage Current
Input
*visit www.iccus.com for complete details
5-YEAr LIMITED WArrANTY*
85 – 264VAC
100 – 240VAC Nominal
47 – 63Hz
<2A rms
<37A at 230VAC cold start
<0.5W
<125µA @ 132VAC @ 60Hz
<175µA @ 264VAC @ 60Hz
<50µA @ 132VAC @ 60Hz
<80µA @ 264VAC @ 60Hz
Medical Switch Mode Power Supply
MVA100 Series
Output Voltage
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection
Output
High Efficiency: Level V
Up to 120W with Forced Air
High Power Density 8.7W/in³
Hold-up Time >24ms at full load
EISA & CEC Compliant
Output Floating
Medical Approval - EN60601-1 Class I
See Table
+/-5%
No minimum load required
<750ms
>24ms at any
input voltage
<1% pk-pk **
110 – 135%
Active - Recoverable; plus
Passive - Non Recoverable
120 – 180%
Shutdown, auto-restart
(hiccup mode)
100 Watts

Related parts for MVA100024A

MVA100024A Summary of contents

Page 1

TECHNICAL SUPPOrT WOrLDWIDE 1-888-357-2280 saleselpac@iccus.com www.iccus.com EUrOPE +44.1383.432920 saleseurope@iccus.com Input Input Voltage Input Frequency Input Current Inrush Current Zero Load Power Consumption Touch Current / Leakage Current Patient Leakage Current Notes *visit www.iccus.com for complete details **Ripple and noise measured ...

Page 2

... MVA100012A 12.0V MVA100015A 15.0V MVA100018A 18.0V MVA100024A 24.0V Notes 1) With convection cooling. Peak load (120W) lasting 500ms with a maximum 10% duty cycle. 2) Sustained output current with minimum 100 LFM. 3) Includes initial setting, line regulation, load regulation, and thermal drift. 4) Typical at 115VAC and full load. ...