Description
POWER SUPPLY 2V 60A OUTPUT
Manufacturer
TDK Corporation
Series
JWSr
Datasheets

Specifications of JWS3002

Power Supply Type
Switching (Open Frame)
Voltage - Output
2V
Number Of Outputs
1
Power (watts)
300W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
2 VDC @ 60A
Size / Dimension
7.48" L x 4.72" W x 3.62" H (190mm x 120mm x 92mm)
Power (watts) - Rated
120W
Operating Temperature
-10°C ~ 60°C
Efficiency
60%
Approvals
CE, CSA, DENTORI, EN, UL, VDE
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
2V
Output Current
60A
Power Rating
120W
Input Voltage
85V AC To 265V AC / 120V DC To 330V DC
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
JWS300-2
Q1022911
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Inrush Current (100 / 200VAC)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Remote On / Off
AC Power Fail
Parallel Connection
Operating Temp. (open frame)
Operating Temp. (with cover)
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Weight (Typ)
Size (WxHxD)
Warranty
*1 non condensing
VDE0160 Approved
5 Year Warranty
Power Factor Corrected
Level B EMI
Not recommended for new designs - see HWS series
MODEL
(*1)
(*1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
mm
mA
ms
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI
JWS50
350
-10ºC~+65ºC, derate linearly to 55% load from 50ºC~65ºC (JWS300-600)
-10ºC~+50ºC, derate linearly to 60% load from 40ºC~50ºC (JWS50-150)
No
Specify as Option /R
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
-10ºC~+60ºC, derate linearly to 60% load from 50ºC~60ºC
JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan
10 - 55Hz (1 minute sweep), 19.6m/s
Single Output Industrial Power Supplies
MAW1202-22
Not Available
Not Available
30 - 90% RH
>100M at 25ºC & 70%RH, Output to Ground 500VDC
14 / 28
JWS75
450
Output to Ground 500VAC (100mA) for 1 min.
EN55011 / EN55022-B, FCC Class B, VCCI-B
85 - 265VAC (47 - 63Hz) or 120 - 330VDC
Benefit
JWS Series
Factory Automation
Test & Measurement
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
No additional Approvals Needed
Lower Cost of Ownership
Supports Global Use
Assists System Compliance
5 Year Warranty
Power factor Corrected
Approved to VDE0160 Machinery Directive
Universal Input (85 - 265VAC)
See side 2
Five Years
JWS100
Meets EN61000-3-2
650
< 196.1 m/s
-30 to +85ºC
10 - 95% RH
<0.02%/ºC
>105%
0.75
Yes
20
MAW1203-22
JWS150
25 / 50
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
850
2
2
constant X, Y, Z 1 hour
Yes
10 - 90% RH
Standard
Standard
Standard
MB1210
JWS300
1900
20 / 40
MB1216
JWS600
3000
51

Related parts for JWS3002

JWS3002 Summary of contents

Page 1

Not recommended for new designs - see HWS series Feature VDE0160 Approved 5 Year Warranty Power Factor Corrected Level B EMI ...

Page 2

Adjust Max Model Voltage Range Curr. Reg mV Reg mV Noise (typ)% JWS300-2 2.0V 1.8 - 2.4 60 JWS600-2 2.0V 1.8 - 2.4 120 JWS50-3/A 3.3V 2.85 ...