SWT100-525 TDK Corporation, SWT100-525 Datasheet

PWR SUP 100W +5 +12 -5V TRIPLE

SWT100-525

Manufacturer Part Number
SWT100-525
Description
PWR SUP 100W +5 +12 -5V TRIPLE
Manufacturer
TDK Corporation
Series
SWT100r
Datasheets

Specifications of SWT100-525

Voltage - Output
±5V, 12V
Number Of Outputs
3
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 8A
2nd Output
12 VDC @ 4A
3rd Output
-5 VDC @ 800mA
Size / Dimension
7.75" L x 4.25" W x 1.77" H (196.9mm x 108mm x 45mm)
Power (watts) - Rated
100W
Operating Temperature
0°C ~ 50°C
Efficiency
74%
Approvals
CSA, DENAN, EN, UL
Line Regulation
1%, 2%
Load Regulation
2%, 4%
4th Output
-
Other names
285-1066
SWT100525
10 OUTPUT VOLTAGE
11 MAX. RIPPLE & NOISE
12 MAX. LINE REGULATION
13 MAX. LOAD REGULATION
14 MAX. TEMPERATURE DRIFT
15 OVER CURRENT PROTECTION ( * 7) -
16 OVER VOLTAGE PROTECTION ( * 8) -
17 HOLD - UP TIME (TYP)
18 OPERATING TEMPERATURE
19 OPERATING HUMIDITY
20 STORAGE TEMPERATURE
21 STORAGE HUMIDITY
22 COOLING
23 EMI
24 WITHSTAND VOLTAGE
25 ISOLATION RESISTANCE
26 VIBRATION
27 SHOCK
28 OUTPUT GROUNDING
29 SAFETY
30 WEIGHT
31 SIZE (W*D*H)
1 NOMINAL OUTPUT VOLTAGE
2 MIN. OUTPUT CURRENT
3 MAX. OUTPUT CURRENT
4 PEAK OUTPUT CURRENT
5 MAX. OUTPUT POWER
6 EFFICIENCY (TYP)
7 INPUT VOLTAGE RANGE
8 INPUT CURRENT (TYP)
9 INRUSH CURRENT (TYP)
CA704-01-01F
*10. When resuming operation in less than 5sec. after power failure, soft start circuit will not limit the in-rush current at turn-on.
NOTES:
ITEMS
*1. At 100VAC, 200VAC and MAX. OUTPUT POWER (Convection cooling), Ta=25°C.
*2. For cases where conformance to various safety specs (UL,CSA, EN) are required to be described as
*3. Please refer to Fig A for measurement determination of line & load regulation and output ripple voltage.
*4. From 85~132VAC / 170~265VAC, constant load.
*5. From Min. load - Full load ( Maximum power ), constant input voltage.
*6. From 0°C ~ +50°C, constant input voltage and load.
*7. Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds.
*8. Over voltage clamping by zener diode.
*9. At standard mounting method, Fig B.
Fig. A
100~120VAC, 200~240VAC, 50/60 Hz on name plate.
(Measure with JEITA RC-9131 probe)
CN2
L: 150mm AWG#18
C1,C3,C5: Film Cap 0.1µF
C2,C4,C6: Elec. Cap 100µF
Bandwidth of scope: 100MHz
GND
GND
GND
+5V
+5V
+5V
NC
+V
+V
-V
L
SWT100 SPECIFICATIONS
( * 1) -
( * 2) -
( * 1) -
( *10) -
( * 3) -
(*3,4) -
(*3,5) -
(*3,6) -
( * 1) -
( * 9) -
C2
C4
MODEL
Measurement point for Vo
Load / Line regulation
m/m
inch
C6
W
V
A
A
A
C3
-
-
-
-
-
-
-
-
-
-
-
-
C1
CH1
I/P-O/P:3kVAC(20mA),I/P-FG:2.5kVAC(20mA),O/P-FG:500VAC(100mA) for 1min
0.5
C5
+5
8
-
Measurement point for
V ripple
10 ~ 55Hz Amplitude ( sweep 1min ) Less than 19.6m/s
A
A
A
SWT100-522
More than 100M at Ta=25°C and 70%RH, Output - FG 500VDC
CH2
97.6
+12
0
4
-
Convection cooling 0 ~ 50°C:100% load; 60°C:70% load
Shipment condition: CH1: ±1%, CH2: ±3%, CH3: ±5%
4.25 x 7.75 x 1.77 (3.75 x 7.25 mounting hole
AC85~265V (Continuously), 47~63 Hz /110~340VDC
Conform to UL1950, CSA950, EN60950, DENTORI
±5V: 120mV;
Automatic recovery,
15A / 100VAC 30A / 200VAC (Ta=25°C)
2.9A(Vin=100VAC) / 1.9A (Vin=200VAC)
Conform to FCC-B, VCCI-2, EN55022B
CH3
All channels common ground (3 terminals)
-12
0.8
0
-
CH1:1%,
CH1:2%,
CH1 +5V fixed, CH2.3 fixed
CH1
17ms (Input 100VAC)
0.5
+5
6V ~ ( CH1 only )
Less than 196.1m/s
108.0 x 196.9 x 45.0
8
Convection cooling
-
±12V: 150mV;
30% ~ 90%RH
-20°C ~ +85°C
10% ~ 95%RH
SWT100-525
CH2: 2%,
CH2: 4%,
0.04%/°C
600g
74%
CH2
+12
92
0
4
-
Component side
O.C.P point: 105% ~
Fig. B
CH3
0.8
-5
CH3: 1%
2
0
±15V: 150 mV
CH3: 2%
-
DENSEI-LAMBDA
CH1
2
0.5
+5
8
-
X ,Y ,Z 1Hr each
3.5mm)
SWT100-5FF
CH2
+15
100
3.2
0
-
CH3
-15
0.8
0
-

Related parts for SWT100-525

SWT100-525 Summary of contents

Page 1

... Less than 196.1m/s - All channels common ground (3 terminals) - Conform to UL1950, CSA950, EN60950, DENTORI - m/m 108.0 x 196.9 x 45.0 inch 4.25 x 7.75 x 1.77 (3.75 x 7.25 mounting hole Measurement point for V ripple Measurement point for Vo Load / Line regulation DENSEI-LAMBDA SWT100-525 SWT100-5FF CH2 CH3 CH1 CH2 + + 0 0 ...

Page 2

SWT 100 OUTPUT DERATING CA704-01-02A Ta (°C) MOUNTING : A MOUNTING : B MOUNTING : C MOUNTING : D 0 100 20 100 40 100 50 100 60 70 OUTPUT DERATING CURVE 100 ...

Related keywords