SWT40-5FF TDK Corporation, SWT40-5FF Datasheet - Page 15

PWR SUP 40W +5 +15 -15V TRIPLE

SWT40-5FF

Manufacturer Part Number
SWT40-5FF
Description
PWR SUP 40W +5 +15 -15V TRIPLE
Manufacturer
TDK Corporation
Series
SWT40r
Datasheets

Specifications of SWT40-5FF

Voltage - Output
5V, ±15V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
15 VDC @ 1.5A
3rd Output
-15 VDC @ 300mA
Size / Dimension
5" L x 3" W x 1.4" H (127mm x 76.2mm x 35.6mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CSA, DENAN, EN, UL
Line Regulation
1%, 2%
Load Regulation
2%, 4%
4th Output
-
Other names
285-1073
SWT405FF
・All specifications are subject to change without notice.
SWT
The input line and output load shall be separated and twist-
ed to improve noise sensitivity. Noise can be eliminated by
attaching a capacitor to the load terminals.
Refer to the following fuse rating when selecting the ex-
ternal fuses that are to be used on input line. Do not use
fast-blow fuse. Fuse rating is specified by inrush current
value at line turn-on.
Do not select the fuse according to input current (RMS)
values under the actual load condition.
● Check if the rated input voltage is connected.
● Check if the wiring of input and output are correct.
● Ensure the input and output connectors are firmly in-
● Check if the wiring material is not too thin.
● Check if output current are more than minimum output
● Check if FG terminal is connected to safety ground.
● Ensure that a large capacitor is not connected on the
serted and the pressing of the connector pins are ex-
actly fixed.
current. CH1 (all model) and CH2 (only SWT30, 40)
output side.
Please use within maximum capacitance shown below.
SERIES
6. Before concluding that the unit is at fault…
5. External Fuse Rating
4. Wiring Method
Select the wire materials to adapt the connector as fol-
lows.
INPUT: AWG#24-#18
OUTPUT: AWG#24-18
● Check whether output current are more than minimum output
SWT100
current.
The output voltage of all channel are stabilized when CH1 (all
model) and CH2 (only SWT30, 40) are more than minimum
output current.
SWT30
SWT40
SWT65
Model
SWT30,SWT40
CH1 (+5V)
50,000uF
50,000uF
50,000uF
8,000uF
SWT100
SWT65
Model
Maximum capacitance
Fuse Rating
CH2 (+V)
10,000uF
10,000uF
2,000uF
6,000uF
3.15A
2.5A
5A
CH3 (−V)
5,000uF
5,000uF
1,000uF
5,000uF
A-287
Alpha II
DLP
FPS
Genesys
HK-A
HWS
JWS-P
JWT
MTW
RKE
RKY
RTW
SWT
UNA
VS
VS-P
ZUP
ZWD-
PAF
ZWQ
ZWS
ZWS-
PAF

Related parts for SWT40-5FF