ZWS30-15 TDK Corporation, ZWS30-15 Datasheet

PWR SUP 15V 2A SNG OUTPUT

ZWS30-15

Manufacturer Part Number
ZWS30-15
Description
PWR SUP 15V 2A SNG OUTPUT
Manufacturer
TDK Corporation
Series
ZWSr
Type
Commercialr
Datasheets

Specifications of ZWS30-15

Power Supply Type
Switching (Open Frame)
Voltage - Output
15V
Number Of Outputs
1
Power (watts)
30W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 2A
Size / Dimension
5.24" L x 2.17" W x 1.02" H (133mm x 55.1mm x 25.9mm)
Power (watts) - Rated
30W
Operating Temperature
-10°C ~ 60°C
Efficiency
77%
Approvals
CE, CSA, EN, UL
Power Supply Output Type
Fixed
No. Of Output Channels
1
Input Frequency
440Hz
Output Voltage
15V
Output Current
2A
Power Rating
30W
Input Voltage
85VAC To 265VAC / 110VDC To 330VDC
Brand/series
ZWS Series
Configuration
Open-Frame
Current, Output
2 A (Max.)
Dimensions
5.24 in. L x 2.17 in. H x 0.118 in. D
Frequency, Operating
47 to 440 Hz
Line Regulation
60 mV
Load Regulation
120 mV
Output
15 VDC @ 2 to 2.4 A
Power, Output
30 W
Power, Rating
30 W
Primary Type
AC-DC
Special Features
PFC
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
-10 to +60 °C
Voltage, Input
85 to 265 VAC
Voltage, Output
15 VDC
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1722
ZWS3015

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZWS30-15
Manufacturer:
LAMBDA
Quantity:
12 000
*1. Operating time at peak output is less than 10sec. ( Duty = 0.35 )
*2. At 100VAC and maximum output current, Ta=25°C.
*3. For cases where conformance to various safety specs (UL, CSA, EN) are
*4. From 85 - 265VAC , constant load.
*5. From Min load-Full load ( Maximum power ), constant input voltage.
*6. From -10 - +50°C, constant input voltage and load.
*7. Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds.
*8. OVP circuit will shutdown output, manual reset.
*9. Refer to Instruction Manual.
*10. Please refer to Fig A for measurement of line & load regulation and output ripple voltage.
*11. At standard mounting method, Fig B.
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
10 Inrush Current(Typ)
11 Output Voltage Range
12 Maximum Ripple & Noise
13 Maximum Line Regulation
14 Maximum Load Regulation
15 Maximum Temperature Drift
16 Over Current Protection
17 Over Voltage Protection
18 Hold-up Time (Typ)
19 Parallel Operation
20 Series Operation
21 Operating Temperature
22 Operating Humidity
23 Storage Temperature
24 Storage Humidity
25 Cooling
26 Withstand Voltage
27 Isolation Resistance
28 Vibration
29 Shock
30 Safety
31 Conducted Noise
32 Weight (Typ)
33 Size (WxHxD)
1 Nominal Output Voltage
2 Minimum Output Current
3 Maximum Output Current
4 Maximum Peak Output Current
5 Maximum Output Power
6 Maximum Peak Output Power
7 Efficiency (Typ)
8 Input Voltage Range
9 Input Current (Typ)
A155-01-01B
ITEMS
required, to be described as 100-240VAC, 50/60Hz on name plate.
ZWS 30 Specifications
(*10) -10 - 0°C mV
MODEL
UL1950
CSA950
EN60950
DENTORI - Built to meet
0 - +60°C mV
(*4,10) mV
(*5,10) mV
(*11) -
(*1) A
(*1) W
(*2) %
(*3) -
(*6) mV
(*7) -
(*8) -
(*2) -
(*9) -
mm 55 x 26 x 133 ( Refer to Outline Drawing )
W
V
A
A
g 270
-
-
-
-
-
- -30 - +85°C
-
- Convection Cooling
-
- More than 100M at 25°C and 70%RH , Output - FG : 500VDC
-
- Less than 20G
- Approved
- Approved
- Approved
- Built to meet EN55011-B,EN55022-B, FCC-ClassB, VCCI-2.
10 - 55Hz Amplitude (Sweep for 1min). Less than 2G, X,Y,Z 1hour each.
ZWS30 ZWS30 ZWS30 ZWS30 ZWS30 ZWS30 ZWS30
85 - 265VAC ( 47 - 440Hz ) or 110 - 330VDC
0.83 at 100VAC, 0.42A at 200VAC
15A at 100VAC, 30A at 200VAC ( Ta = 25°C Cold Start )
±10%
125% -
140% -
17mS at 100VAC, 30W, Ta = 25°C
Impossible
Possible
-10 - +50°C( 100% ), +60°C ( 70% )
30 - 90%RH (No dewdrop)
10 - 95%RH (No dewdrop)
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
23.76
19.8
120
160
3.3
7.2
70
20
40
60
-3
0
6
*
120
160
7.2
30
36
75
20
40
60
-5
5
0
6
150
180
140
-12
2.5
12
30
36
77
48
96
0
3
*:For delivery, contact to our sales office.
150
180
120
180
-15
2.4
15
30
36
77
60
0
2
37.44
1.56
31.2
200
200
150
280
-24
1.3
24
78
96
0
NEMIC-LAMBDA
Built to meet
Built to meet
Built to meet
38.88
1.08
32.4
300
300
144
240
420
-36
0.9
36
78
0
*
40.32
0.84
33.6
400
400
192
300
560
-48
0.7
48
78
0
*

Related parts for ZWS30-15

ZWS30-15 Summary of contents

Page 1

... Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. *8. OVP circuit will shutdown output, manual reset. *9. Refer to Instruction Manual. *10. Please refer to Fig A for measurement of line & load regulation and output ripple voltage. *11. At standard mounting method, Fig B. * ZWS30 ZWS30 ZWS30 ZWS30 ZWS30 ZWS30 ZWS30 - ...

Page 2

ZWS 30 OUTPUT DERATING Ta (°C) MOUNTING : A -10 - +30 100 40 100 45 100 50 100 OUTPUT DERATING CURVE 100 - MOUNTING : B MOUNTING : ...

Related keywords