2938578 Phoenix Contact, 2938578 Datasheet - Page 2

PWR SUPPLY 2.5A 100-240AC 24DC

2938578

Manufacturer Part Number
2938578
Description
PWR SUPPLY 2.5A 100-240AC 24DC
Manufacturer
Phoenix Contact
Series
Quintr
Type
Industrialr
Datasheets

Specifications of 2938578

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
10W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 2.5A
Size / Dimension
4.92" L x 2.17" W x 5.12" H (125mm x 55mm x 130mm)
Power (watts) - Rated
10W
Operating Temperature
-25°C ~ 70°C
Efficiency
86%
Approvals
ABS, CB, cUL, DNV, GL, GOST, UL
Product
Switching
Commercial/medical
Commercial
Output Power Rating
60 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
24 VDC
Output Current (channel 1)
2.5 A
Mounting Style
DIN Rail
Brand/series
QUINT-PS
Configuration
Enclosed
Current, Rating
2.5 A
Frequency
45 to 65 Hz
Height
130 mm
Operation
Switching
Output
24 VDC @ 2.5 A
Phoenix Part Number
QUINT-PS-100-240AC/24DC/2.5
Power, Output
8 W
Primary Type
AC-DC
Temperature, Operating, Maximum
+70 °C (Ambient)
Temperature, Operating, Minimum
-25 °C (Ambient)
Voltage, Input
85 to 264/90 to 350 VAC/VDC
Voltage, Output
24 VDC
Voltage, Rating
85 to 264 VAC
Width
55 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
277-1660
QUINT-PS-100-240AC/24DC/ 2.5
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2938578
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
DC frequency range
Current consumption
Nominal power consumption
Inrush surge current
Power failure bypass
Input fuse
Permissible backup fuse
Name of protection
Protective circuit/component
Output data
Nominal output voltage
Setting range of the output voltage
Output current
Derating
Connection in parallel
Connection in series
Max. capacitive load
Current limitation
Control deviation
Residual ripple
Peak switching voltages nominal load
Maximum power dissipation idling
Power loss nominal load max.
General data
Width
Height
Depth
Order No.: 2938578
0 Hz
Approx. 0.86 A (120 V AC)
Approx. 0.47 A (230 V AC)
60 W
< 20 A (typical)
> 30 ms (120 V AC)
> 130 ms (230 V AC)
5 A (slow-blow, internal)
6 A
10 A
16 A (characteristic B)
Transient surge protection
Varistor
24 V DC ±1%
22.5 V DC ... 28.5 V DC
2.5 A (up to 60°C)
3.75 A (with POWER BOOST)
From +60°C 2.5% per Kelvin
Yes, for redundancy and increased capacity
Yes
Unlimited
Approx. I
< 1 % (change in load, static 10% ... 90%)
< 2 % (change in load, dynamic 10% ... 90%)
< 0.1 % (change in input voltage ±10%)
< 10 mV
< 40 mV
< 2 W
< 8 W
55 mm
130 mm
125 mm
PP
PP
BOOST
(with nominal values)
(20 MHz)
= 3.75 A (for short circuit)
Mar 23, 2010