GLC110-12G SL Power Electronics Manufacture of Condor/Ault Brands, GLC110-12G Datasheet - Page 2

PWR SPLY SWITCHER 110W 12V

GLC110-12G

Manufacturer Part Number
GLC110-12G
Description
PWR SPLY SWITCHER 110W 12V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLC110r
Datasheet

Specifications of GLC110-12G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
110W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 6.3A
Size / Dimension
7" L x 4.25" W x 1.3" H (177.8mm x 108mm x 33mm)
Power (watts) - Rated
110W
Operating Temperature
0°C ~ 50°C
Efficiency
85%
Approvals
CE, CSA, IEC, UL
Line Regulation
2%
Load Regulation
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
271-2300
* Add “G” suffix to part number for RoHS compliant model. Contact factory for availability.
A. Rating with unrestricted convection cooling. Total power not to exceed 75 W; no output can exceed rated current.
B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W.
C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load.
SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 02/11/10.
Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
GLC110/GLM110 MECHANICAL SPECIFICATIONS
Commercial
Model
GLC110-212
GLC110-215
GLC110-524
GLC110-12
GLC110-15
GLC110-24
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (C)
Altitude
Vibration (B)
Medical
Model
GLM110-212
GLM110-215
GLM110-524
GLM110-12
GLM110-15
GLM110-24
Suffix*
RoHS
G
G
G
G
G
G
OPERATING
0 to 50°
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
Output
No.
1
2
1
2
1
2
1
1
1
pk
rms’
0.003 g
Output
+12 V
+15 V
+24 V
-12 V
-15 V
+5 V
12 V
15 V
24 V
2
/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
Minumum
Output
1 A
0 A
1 A
0 A
1 A
0 A
0 A
0 A
0 A
rms’
pk
0.026 g
2
/Hz
Normal (A)
Output
6.3 A
2.5 A
2.5 A
3.2 A
1.5 A
6.3 A
3.2 A
5 A
5 A
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derated output current and toal
output power by 2.5% per °C above 50°C.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
Forced Air
9.1 A
7.3 A
4.6 A
9.1 A
7.3 A
4.6 A
3 A
3 A
2 A
(B)
Output Peak
4.75 A
9.5 A
7.7 A
2.5 A
9.5 A
7.7 A
4 A
5 A
4 A
Noise P-P
100 mV
120 mV
120 mV
150 mV
200 mV
120 mV
150 mV
240 mV
50 mV
15.6 ± 1.1 V
18.5 ± 1.5 V
15.6 ± 1.1 V
18.5 ± 1.5 V
6.2 ± 0.6 V
28 ± 2.5 V
28 ± 2.5 V
OVP
Total Regu-
lation ( C )
2%
2%
2%
2%
2%
2%
2%
2%
2%

Related parts for GLC110-12G