ZUP120-1.8/U TDK Corporation, ZUP120-1.8/U Datasheet

PWR SUP BENCH PROG 0-120V 216W

ZUP120-1.8/U

Manufacturer Part Number
ZUP120-1.8/U
Description
PWR SUP BENCH PROG 0-120V 216W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP120-1.8/U

Load Regulation
0.01%
Voltage - Output
0 ~ 120V
Number Of Outputs
1
Power (watts)
216W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 120 VDC @ 1.8A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
216W
Operating Temperature
0°C ~ 50°C
Efficiency
82%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
120V
Output Current
1.8A
Power Rating
216W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 70 mV
Brand/series
ZUP
Current, Output
1.8 A
Display Type
Digital Meter
Power, Output
216 W
Power, Rating
216 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
80 mV @ 20 MHz BW
Voltage, Output
120 VDC
Voltage, Ripple
30 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1671
ZUP1201.8/U
S p e c i f i c a t i o n s
ITEMS
Load Regulation
Line Regulation
Recovery Time
Temperature Coefficient
Temperature Drift(2)
Up programming response time
Down prog. resp. time (CV)
Down prog. resp. time (CV)
Load Regulation
Line Regulation
Temperature Coefficient
Temperature Drift(2)
Prog Voltage resolution
Prog Voltage accuracy
Prog Current resolution
Prog Current accuracy
Overvoltage Shutdown
Thermal Protection
Display - Voltage
Display - Current
Display - Status
Remote On/Off
Output Good
Voltage & Current Programming
Remote Sense
Communication Interface
Series & Parallel Operation
AC Input Voltage range
Inrush Current (100/200VAC) (3)
Hold Up Time (Typ) at 100VAC
Power Factor Correction
Temperature Range
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration & Shock (non-op.)
Safety Agency Approvals
Conducted & Radiated EMI
Warranty
Notes:
(1)
(2)
(3)
Recovery to within +/-50mV after load change of 50-100%
Over 8 hour period following 30 minute warm up time
25°C ambient (cold start)
MODELS
(1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
Cond.
Zero
Full
CC
CC
CC
CC
CV
CV
CV
CV
CV
CV
ms
V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
.02%+5mV
3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
250ms
0 - 7.5
ZUP6
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
1ms
0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
Series: Up to two units; Parallel: Up to five units in master-slave configuration
0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models
15/30A, 200W models, 15A, 400W models, 30A, 800W models
100ppm/°C from rated current after 30 minute warm up time
1mV + 0.005% over 85 - 132 or 170 - 265VAC line change
.02%+8mV
50 - 60ms
EN55022-B conducted, A radiated, FCC Class B conducted,
3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
350ms
ZUP10
0.5ms
0 - 13
CV / CC, Alarm, Foldback, Local/Remote, On/Off
Operating: 30 - 90% RH, Storage 10 - 95%RH
Complies with EN61000-3 Class A (0.99 typ)
Operating: 0 - 50°C; Storage: -20 to +70°C
2mV + 0.005% over 0 - 100% load change
By either Voltage (0-4V) or Resistance (0-4k)
RS232 & RS485 standard, IEEE488 optional
A radiated, VCCI-2 conducted, -1 radiated
Up to 0.5V compensation per output cable
30ppm/°C following 30 minute warm up
Better than 0.028% of rated voltage
ZUP Series
Zero up programmable power supplies
.02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV
Better than 0.03% of rated voltage
UL3111-1, EN61010-1, CE Mark
0.01% + 2mV change in output
TTL signal or dry contact relay
ZUP20
400ms
0 - 24
Over temperature protected
>100M at 25°C & 70%RH
Constant Voltage / Constant Current
Last Setting Memory
Digital Meters
Built-in RS232 & RS485 Interface w/ GPIB optional
Bench or Rack Mount
Embedded Microprocessor Controller
Voltage up to 120V, Current up to 132A
50ms (70ms ZUP60-14)
85-265VAC (47-63Hz)
Open Collector
0.4% + 40mA
Internal fan
Three Years
500ms
20
ZUP36
0 - 40
0.2ms
750ms
ZUP60
0 - 66
ZUP80
600ms
0 - 88
80ms
ZUP120
0 - 132
120ms
800ms
85

Related parts for ZUP120-1.8/U

ZUP120-1.8/U Summary of contents

Page 1

... Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100M at 25°C & 70%RH Vibration:10-55Hz(1 min.) 2G constant when correctly mounted; Shock: <20G UL3111-1, EN61010-1, CE Mark EN55022-B conducted, A radiated, FCC Class B conducted, A radiated, VCCI-2 conducted, -1 radiated Three Years ZUP36 ZUP60 ZUP80 0.2ms 80ms 500ms 750ms 600ms ZUP120 120ms 800ms 0 - 132 85 ...

Page 2

... ZUP60-3.5/U 0-60 0-3.5 ZUP60-7/U 0-60 0-7 ZUP60-14/U 0-60 0-14 ZUP80-2.5/U 0-80 0-2.5 ZUP80-5/U 0-80 0-5 ZUP120-1.8/U 0-120 0-1.8 ZUP120-3.6/U 0-120 0-3 & Option Model Suffix Front panel terminals (20A max Front panel terminals (20A max IEC320 cable USA plug ...

Related keywords