JWS70P24/508 TDK Corporation, JWS70P24/508 Datasheet

PWR SUP 24V 3A SNG OUTPUT

JWS70P24/508

Manufacturer Part Number
JWS70P24/508
Description
PWR SUP 24V 3A SNG OUTPUT
Manufacturer
TDK Corporation
Series
JWSr
Datasheets

Specifications of JWS70P24/508

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
70W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 3A
Size / Dimension
7.4" L x 3.62" W x 1.97" H (188mm x 91.9mm x 50mm)
Power (watts) - Rated
72W
Efficiency
80%
Approvals
EN, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1401
JWS70P-24/508
JWS70P24
*10. Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz).
*11. Power Supply will recover in case of lower the temperature.
*12. Ratings - Derating at standard mounting.
*13. As for DENAN, built to meet at 100VAC.
*1. Operating time at peak output is less than 10sec. (Duty<=0.5)
*2. At 100/200VAC, Ta=25°C and average output power.
*3. For cases where conformance to various safety specifications (UL, CSA, EN) are required,
*4. Measure with JEITA RC-9131 probe, Bandwidth of scope :100MHz.
*5. 85 ~ 265VAC , constant load.
*6. No load - Average load, constant input voltage.
*7. Constant current limit with automatic recovery.
*8. OVP circuit will shut down output, manual reset (Line recycle).
*9. At 100/200VAC nominal output voltage and average output current.
*Read instruction manual carefully, before using the power supply unit.
10 PFHC
11 Power Factor (100/200VAC)(Typ) (*2)
12 Output Voltage Range
13 Maximum Ripple & Noise
14 Maximum Line Regulation
15 Maximum Load Regulation
16 Temperature Coefficient
17 Over Current Protection
18 Over Voltage Protection
19 Hold-up Time (Typ)
20 Leakage Current
21 Thermal protection
22 Remote Sensing
23 Parallel Operation
24 Series Operation
25 Operating Temperature
26 Operating Humidity
27 Storage Temperature
28 Storage Humidity
29 Cooling
30 Withstand Voltage
31 Isolation Resistance
32 Vibration
33 Shock (In package)
34 Safety
35 Conducted Emission
36 Radiated Emission
37 Weight (Typ.)
38 Size (W x H x D)
1 Nominal Output Voltage
2 Average Output Current
3 Peak Output Current
4 Average Output Power
5 Peak Output Power
6 Efficiency (Typ)
7 Input Voltage Range
8 Input Current (100/200VAC)(Typ) (*2)
9 Inrush Current(Typ)
ITEMS
input voltage range will be 100 ~ 240VAC (50/60Hz).
A180-01-01/508-A
JWS70P/508
=NOTES=
- Load (%) is percent of average output power or average output current, whichever is greater.
- As for other mountings, refer to derating curve (A180-01-02_).
(*4)
0 ~ +60°C -
-10 ~ 0°C -
MODEL
(*10) -
(*11) -
(*12) -
(*13) -
(*1) -
(*1) -
(*2) -
(*3) -
(*5) -
(*6) -
(*7) -
(*8) -
(*9) -
mm
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SPECIFICATIONS
Approved by UL508,CSA C22.2 No.14,UL1950,CSA950,EN60950,VDE0160.
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
More than 100M at 25°C and 70%RH Output - FG … 500VDC
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A.
Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A.
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
-10 ~ +60°C ( -10 ~ +50°C:100%, +60°C:60%)
At no operating, 10 ~ 55Hz (Sweep for 1min)
50 x 92 x 188 ( Refer to Outline Drawing )
Output - FG : 500VAC (100mA) for 1min
19.6 m/s
Built to meet EN61000-3-2
30 ~ 90%RH (No dewdrop)
85 ~ 265VAC (47 ~ 63Hz)
10 ~ 95%RH (No dewdrop)
2
Built to meet DENAN.
Less than 196.1 m/s
Less than 0.02%/°C
Convection Cooling
Constant, X, Y, Z 1hour each.
JWS70P-24/508
27.6V ~ 32.4V
21.6V ~ 26.4V
-30 ~ +85°C
1.0A/0.5A
0.98/0.92
Built-in
240mV
360mV
192mV
6.12A ~
Possible
Possible
144W
96mV
20ms
72W
700g
80%
24V
3A
6A
-