LS150-5 TDK Corporation, LS150-5 Datasheet - Page 5

POWER SUPPLY 5V 26A SGL OUTPUT

LS150-5

Manufacturer Part Number
LS150-5
Description
POWER SUPPLY 5V 26A SGL OUTPUT
Manufacturer
TDK Corporation
Series
LSr
Datasheets

Specifications of LS150-5

Number Of Outputs
1
Voltage - Output
5V
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 132VAC, 176 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 26A
Size / Dimension
7.8" L x 3.9" W x 1.5" H (198.1mm x 99.1mm x 38.1mm)
Power (watts) - Rated
130W
Operating Temperature
-25°C ~ 70°C
Efficiency
79%
Approvals
CE, EN, IEC, UL
Output Current (max)
26A
Input Voltage
88 to 132/176 to 264V
Output Voltage
5V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
38.1mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
285-1817
LS1505

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LS150-5
Manufacturer:
TDK-LAMBDA
Quantity:
617
4. Isolation / Withstand Voltage
4-1. Isolation Test
Isolation resistance between output and FG (chassis) shall be more than 100MΩ at 500VDC. For safety, voltage setting
of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test.
4-2. Withstand Voltage
This series is designed to withstand 3.0kVAC between input and output, 1.5kVAC between input and FG (chassis) and
500VAC between output and FG (chassis) each for 1 minute. When testing withstand voltage, set current limit of with-
stand voltage test equipment at 20mA ( Output-FG (chassis) : 100mA ). The applied voltage must be gradually increased
from zero to testing value and then gradually decreased for shut down. When timer is used, the power supply may be
damaged by high impulse voltage at timer switch on and off. Connect input and output as follows :
(a) Input ~ FG (chassis) : solid line
(b) Input ~ Output : dotted line
1.5kVAC, 1min (20mA)
3kVAC, 1min ( 20mA )
(a) Output ~ FG (chassis) : 500VDC, 100MΩ or more
Isolation
Tester
Withstand
Voltage
Tester
AC(L)
AC(N)
FG
AC(L)
AC(N)
FG
+ V
- V
+V
- V
+V
+V
-V
-V
4
Withstand
Voltage
Tester
(c) Output ~ FG (chassis) : 500VAC, 1min (100mA)
FG
AC(L)
AC(N)
LS
INSTRUCTION MANUAL
TDK-Lambda
25-150
Series
+V
+V
-V
-V

Related parts for LS150-5