S82K-03024 Omron, S82K-03024 Datasheet - Page 3

POWER SUPPLY 24V 1.3A DIN RAIL

S82K-03024

Manufacturer Part Number
S82K-03024
Description
POWER SUPPLY 24V 1.3A DIN RAIL
Manufacturer
Omron
Series
S82Kr
Datasheet

Specifications of S82K-03024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
30W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 1.3A
Size / Dimension
3.58" L x 3.54" W x 2.95" H (91mm x 90mm x 75mm)
Power (watts) - Rated
30W
Operating Temperature
-10°C ~ 50°C
Efficiency
66%
Approvals
CE, CSA, cUL, cUR, UL, VDE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
S82K03024
Z1184
Note: 1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the power supply may not start.
Item
Efficiency (typical)
Input Voltage
Out-
put
(See
note
4.)
Addi-
tion-
al
func-
tions
Oth-
er
(See note 2.)
Frequency
Current
(See note 3.)
Power Factor
Harmonic current emissions ---
Leakage current
(See note 3.)
Inrush current
(See note 3.)
Noise filter
Voltage Adjustment Range
Ripple (See note 3.)
Input variation influence
Load variation influence
(rated input voltage)
Temperature variation influ-
ence (See note 3.)
Startup time
Hold time (See note 3.)
Overload protection
(See note 6.)
Overvoltage protection
Undervoltage alarm indica-
tion
Undervoltage alarm output
Parallel operation
Operating ambient tempera-
ture
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved stan-
dards
Weight
2. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards.
3. Defined with a 100% load and the rated input voltage (100 or 200 VAC.)
4. The output specification is defined at the power output terminals.
5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +10% of the voltage adjustment range. (+15% for S82K-03012/-03024)
6. Refer to Overload Protection on page 8 for details.
7. When using the 90-W model at an ambient temperature of 25°C or less, the overload protection function will operate at 101% to 111% of the rated output
8. Parallel operation is set with the Parallel/Single Operation Selector.
9. To meet Class-2 requirements with the 100-W, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be wired in
Refer to Overload Protection on page 8 for details.
Do not use the Inverter output for the Power supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of
the Power Supply may result in ignition or burning. There is no polarity.
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
current. When using the 90-W model at an ambient temperature exceeding 25°C, the overload protection function will operate at 92% to 111% of the rated
output current.
series with the load to be connected to the Power Supply. Only then can the Power Supply output be considered as meeting Class 2.
Power ratings
(See note 1.)
AC
DC
100-V input 1.3 A max.
200-V input 0.8 A max.
100-V input 0.5 mA max.
200-V input 1 mA max.
100-V input 25 A max. (for cold start at 25°C)
200-V input 50 A max. (for cold start at 25°C)
Detection
current
Conducted
Emissions
Radiated
Emissions
UL
cUL
cUR
EN/VDE
80% min. (Varies depending on specifications)
100 to 240 VAC (85 to 264 VAC) 100 V (85 to 132 VAC)/200 V (170 to 264 VAC) Selectable
Not possible
50/60 Hz (47 to 450 Hz)
---
Yes
±10% (with V. ADJ) (−10% to 15% for S82K-05024) (See note 5.)
2% (p-p) max.
0.5% max. (at 85 to 264 VAC in-
put, 100% load)
1.5% max. (0 to 100% load)
0.05%/°C max.
100 ms max. (up to 90% of out-
put voltage at rated input and
output)
20 ms min.
105% to 160% of rated load
current, gradual current in-
crease, voltage drop intermit-
tent operation, automatic reset
No
Yes (color: red)
No
No
Refer to the derating curve in Engineering Data. (with no icing or condensation)
−25 to 65°C (with no icing or condensation)
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and all outputs)
2.0 kVAC for 1 min. (between all inputs and PE terminals)
1.0 kVAC for 1 min. (between all outputs and PE terminals)
20 mA
100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
300 m/s
Yes (color: green)
Conforms to EN61204-3
EN55011 Class B and based
on FCC Class B
Conforms to EN61204-3 EN55011 Class B
Conforms to EN61204-3 High severity levels
UL508 (Listing; Class 2: Per UL1310), Class 2 (excluding dual output models) (See note
9.), UL60950-1
CSA C22.2 No.14 (Class 2: Per No. 223, excluding dual output models) (See note 9.)
CSA No. 60950-1
EN50178 (= VDE0160), EN60950-1 (= VDE0805 Teil 1)
Based on VDE0106/P100
400 g max.
2
, 3 times each in ±X, ±Y, ±Z directions
50 W
2.5 A max.
1.5 A max.
0.5% max. (at 85 to 132 VAC input /170 to 264 VAC input, 100% load)
200 ms max.
105% to 160% of rated load current, inverted L drop, automatic reset (See note 7.)
Yes
Conforms to EN61204-3 EN55011 Class B and based on FCC Class A
600 g max.
S82K
90 W
Yes (up to 2 units.)
Single output
100 W
50/60 Hz (47 to 63 Hz)
0.7 min. (at 200 VAC input, at rated output), 100 V: unlimited
Conforms to EN6100-3-2 (200-V only)
±10% (with V. ADJ) (See note 5.)
No
150 m/s
UL508 (Listing; Class 2: Per UL1310), Class 2 (excluding
dual output models) (See note 9.), UL60950-1
CSA C22.2 No.14 (Class 2: Per No. 223, excluding dual out-
put models) (See note 9.)
CSA No. 60950-1
EN50178 (= VDE0160), EN60950-1 (= VDE0805 Teil 1)
Based on VDE0106/P100
1000g max.
2
, 3 times each in ±X, ±Y, ±Z directions
90 W
S82K-P
Yes (up to 2 units.) (See note 8.)
100 W
S82K
3

Related parts for S82K-03024