ZUP36-6/U TDK Corporation, ZUP36-6/U Datasheet - Page 56

PWR SUP BENCH PROG 0-36V 216W

ZUP36-6/U

Manufacturer Part Number
ZUP36-6/U
Description
PWR SUP BENCH PROG 0-36V 216W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP36-6/U

Load Regulation
0.01%
Voltage - Output
0 ~ 36V
Number Of Outputs
1
Power (watts)
216W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 36 VDC @ 6A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
216W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
36V
Output Current
6A
Power Rating
216W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 20 mV
Brand/series
ZUP
Current, Output
6 A
Display Type
Digital Meter
Power, Output
216 W
Power, Rating
216 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
36 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1678
ZUP366/U
6.1
This chapter contains maintenance and calibration information for the ZUP power supply series.
6.2 UNITS UNDER WARRANTY
6.3 PERIODIC MAINTENANCE
6.4 ADJUSTMENT AND CALIBRATION
6.5 PART REPLACEMENT AND REPAIRS.
Units requiring repair during the warranty period should be returned to a Nemic-Lambda authorized
service facility. Refer to the address listing on the back cover of this user’s manual. Unauthorized
repairs performed by other than authorized service facilities may void the warranty.
No routine maintenance of the ZUP power supply is required except for periodic cleaning. To clean,
disconnect the unit from the AC supply and allow 30sec for discharging internal voltage. The front panel
and the metal surfaces should be cleaned using a dry cloth. Use low pressure compressed air to blow
dust from the unit.
No internal adjustment or calibration are required. Units that are returned for service will be calibrated
at the service facility. There is NO REASON to open the ZUP cover.
As repairs are made only by the manufacturer of authorized service facilities, no part replacement
information will be discussed here. In case of failure, unusual or erratic operation of the unit, contact a
Nemic-Lambda sales or service facility nearest you. Please refer to the Nemic-Lambda sales offices
listed on the back cover of this user’s manual.
6.6 FUSE RATINGS
ZUP200 Series(ZUP6-33,ZUP10-20,ZUP20-10,ZUP36-6,ZUP60-3.5,ZUP80-2.5,ZUP120-1.8) : T8A 250V
ZUP400 Series(ZUP6-66,ZUP10-40,ZUP20-20,ZUP36-12,ZUP60-7,ZUP80-5,ZUP120-3.6) : T10A 250V
ZUP800 Series (ZUP6-132, ZUP10-80, ZUP20-40, ZUP36-24, ZUP60-14): F20A 250V