SWS15024 TDK Corporation, SWS15024 Datasheet - Page 3

PWR SUP 24V 6.3A SNG OUTPUT

SWS15024

Manufacturer Part Number
SWS15024
Description
PWR SUP 24V 6.3A SNG OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Commercialr
Datasheets

Specifications of SWS15024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 6.3A
Size / Dimension
7.8" L x 3.9" W x 2" H (198.1mm x 99.1mm x 50.8mm)
Power (watts) - Rated
151.2W
Operating Temperature
-10°C ~ 70°C
Efficiency
85%
Approvals
CE, CSA, EN, UL
Line Regulation
5%
Load Regulation
5%
Brand/series
SWS Series
Configuration
Enclosed
Current, Output
6.3 A (Max.)
Dimensions
3.9 in. W x 2 in. H x 7.8 in. D
Frequency, Input
47 to 63 Hz
Output
24 VDC @ 6.3 A
Power, Output
150 W
Primary Type
AC-DC
Special Features
PFC
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
-10 to +70 °C
Voltage, Input
85 to 265/120 to 370 VAC/VDC
Voltage, Output
24 VDC
Output Current (max)
6.3A
Input Voltage
85 to 265V
Output Voltage
24V
Output Power (max)
150W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
50.8mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Desktop
Pin Count
7
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1614
SWS150-24
CA732-01-03A
* Read instruction manual carefully , before using the power supply unit.
* 1 : At maximum output power, nominal input voltage, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
* 4 : Please refer to Fig A for measurement of line & load regulation, ripple and noise voltage.
* 5 : 85 - 265VAC, constant load.
* 6 : No load - Full load(Maximum power), constant input voltage.
* 7 : Constant current limit with automatic recovery.
* 8 : OVP circuit will shutdown output, manual reset (Re power on).
* 9 : Measured by each measuring method of UL, CSA, EN.
*10: Refer to Output Derating Curve (CA732-01-02_) for details of output derating
*11: Operating period at peak output current is less than 5sec.(Duty<=0.35).
10 PFHC
11 Power Factor (Typ)
12 Output Voltage Range
13 Ripple and Noise
14 Line Regulation
15 Load Regulation
16 Temperature Coefficient
17 Over Current Protection
18 Over Voltage Protection
19 Hold-Up Time (Typ)
20 Leakage current
21 Series Operation
22 Operating Temperature
23 Operating Humidity
24 Storage Temperature
25 Storage Humidity
26 Cooling
27 Withstand Voltage
28 Isolation Resistance
29 Vibration
30 Safety
31 EMI
32 Immunity
33 Weight (Typ)
34 Dimension
1 Nominal Output Voltage
2 Maximum Output Current
3 Peak Output Current
4 Maximum Output Power
5 Peak Output Power
6 Efficiency (Typ)
7 Input Voltage Range
8 Input Current (Typ)
9 Inrush Current (Typ)
Ripple & noise are measured at 20MHz by using a 12'' twisted pair terminated with a 0.1uF and 47uF capacitor.
Avoid to operate at overload or dead short for more than 30seconds.
versus ambient temperature and mounting method .
(Average output power and current is less than Maximum output power and current)
ITEMS
= NOTES=
(115/230VAC)
(115/230VAC)
(115/230VAC)
(115/230VAC)
(115/230VAC) ( * 1, 4 ) mV
MODEL
( * 4, 5 ) mV
( * 4, 6 ) mV
( * 11 )
( * 11 ) W
( * 10 )
( * 1 ) %
( * 2 )
( * 1 )
( * 3 )
( * 1 )
( * 7 )
( * 8 )
( * 1 )
( * 9 )
( * 1 )
( * 1 )
SWS150 SPECIFICATIONS
mm
W
V
A
A
A
V
A
V
g
More than 100M
0.75mA Max, 0.25mA(Typ) at 115VAC / 0.5mA(Typ) at 230VAC
Input - Output : 3.0kVAC (20mA), Input - FG : 2.0kVAC (20mA)
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
16A at 115VAC, 32A at 230VAC, Ta=25
Built to meet FCC-Class B, EN55011/EN55022-B
- 10 ~ + 60 °C (Refer to Output Derating Curve)
At no operating, 10 - 55Hz ( sweep for 1min )
Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
85 ~ 265VAC (47-63Hz) or 120 ~ 370VDC
Output - FG : 500VAC (100mA) for 1min.
51 x 99 x 198 (Refer to Outline Drawing)
19.6m/s
at Ta=25°C and 70%RH, Output - FG : 500VDC
30 ~ 90 %RH (No dewdrop)
Built to meet EN61000-3-2
10 ~ 95%RH (No dewdrop)
2
Constant, X, Y, Z 1hour each
Less than 0.02%/°C
Convection cooling
SWS150-28
- 30 ~ +85°C
TB1
25.2~30.8
32.2~37.8
0.99 / 0.95
1.8 / 0.9
Possible
Measurement point for Vo Line/Load
Regulation, and ripple and noise.
82 / 85
151.2
20ms
6.1~
168
180
112
168
750
5.4
28
6
+V
-V
o
Fig. A
C, Cold Start