SWS10024 TDK Corporation, SWS10024 Datasheet

PWR SUP 24V 4.3A SNG OUTPUT

SWS10024

Manufacturer Part Number
SWS10024
Description
PWR SUP 24V 4.3A SNG OUTPUT
Manufacturer
TDK Corporation
Series
SWSr
Type
Commercialr
Datasheets

Specifications of SWS10024

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 4.3A
Size / Dimension
7.4" L x 3.78" W x 1.77" H (188mm x 96mm x 45mm)
Power (watts) - Rated
103.2W
Operating Temperature
-10°C ~ 60°C
Efficiency
84%
Approvals
CSA, EN, UL
Brand/series
SWS Series
Configuration
Enclosed
Current, Output
4.3 A (Max.)
Dimensions
3.78 in. W x 1.77 in. H x 7.4 in. D
Frequency, Input
47 to 63 Hz
Output
24 VDC @ 4.3 A
Power, Output
100 W
Primary Type
AC-DC
Special Features
PFC
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
-10 to +70 °C
Voltage, Input
85 to 265/120 to 370 VAC/VDC
Voltage, Output
24 VDC
Output Current (max)
4.3A
Input Voltage
85 to 265V
Output Voltage
24V
Output Power (max)
100W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
70C
Mounting Style
Desktop
Pin Count
7
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1610
SWS100-24
CA731-01-01B
* Read instruction manual carefully , before using the power supply unit.
* 1 : At maximum output power, nominal input voltage, Ta = 25°C.
* 2 : For cases where conformance to various safety specs ( UL, CSA, EN ) are required, to be described as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
* 4 : Please refer to Fig A for measurement of line & load regulation, ripple and noise voltage.
* 5 : 85 - 265VAC, constant load.
* 6 : No load - Full load(Maximum power), constant input voltage.
* 7 : Constant current limit with automatic recovery.
* 8 : OVP circuit will shutdown output, manual reset (Re power on).
* 9 : Measured by each measuring method of UL, CSA, EN.
*10: Refer to Output Derating Curve (next page) for details of output derating
10 Output Voltage Range
11 Ripple and Noise
12 Line Regulation
13 Load Regulation
14 Temperature Coefficient
15 Over Current Protection
16 Over Voltage Protection
17 Hold-Up Time (Typ)
18 Leakage current
19 Series Operation
20 Operating Temperature
21 Operating Humidity
22 Storage Temperature
23 Storage Humidity
24 Cooling
25 Withstand Voltage
26 Isolation Resistance
27 Vibration
28 Safety
29 EMI
30 Immunity
31 Weight (Typ)
32 Dimension
1
2
3
4
5
6
7
8
9
Nominal Output Voltage
Maximum Output Current
Maximum Output Power
Efficiency (Typ)
Input Voltage Range
Input Current (Typ)
Inrush Current (Typ)
PFHC
Power Factor (Typ)
Ripple & noise are measured at 20MHz by using a 12'' twisted pair terminated with a 0.1uF and 47uF capacitor.
Avoid to operate at overload or dead short for more than 30seconds.
versus ambient temperature and mounting method .
ITEMS
= NOTES=
(115/230VAC) ( * 1, 4 ) mV
115/230VAC)
115/230VAC)
115/230VAC)
115/230VAC)
( * 4, 5 ) mV
( * 4, 6 ) mV
MODEL
( * 10 )
( * 1 )
( * 1 )
( * 1 )
( * 1 )
( * 1 )
( * 1 )
( * 2 )
( * 3 )
( * 7 )
( * 8 )
( * 9 )
SWS100 SPECIFICATIONS
mm
W
V
%
V
V
A
A
A
g
SWS100-3
2.97~3.63
3.79~4.95
0.9 / 0.5
69 / 70
100
21~
3.3
20
66
20
40
More than 100MΩ at Ta=25°C and 70%RH, Output - FG : 500VDC
0.75mA Max, 0.25mA(Typ) at 115VAC / 0.5mA(Typ) at 230VAC
Input - Output : 3.0kVAC (20mA), Input - FG : 2.0kVAC (20mA)
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
16A at 115VAC, 32A at 230VAC, Ta=25oC, Cold Start
Built to meet FCC-Class B, EN55011/EN55022-B
- 10 ~ + 60 °C (Refer to Output Derating Curve)
SWS100-5
5.75~6.95
At no operating, 10 - 55Hz ( sweep for 1min )
Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
85 ~ 265VAC (47-63Hz) or 120 ~ 370VDC
4.5~5.5
75 / 77
Output - FG : 500VAC (100mA) for 1min.
45 x 96 x 188 (Refer to Outline Drawing)
100
100
21~
19.6m/s
20
20
40
5
30 ~ 90 %RH (No dewdrop)
Built to meet EN61000-3-2
10 ~ 95%RH (No dewdrop)
2
Constant, X, Y, Z 1hour each
Less than 0.02%/°C
Convection cooling
Measurement point for Vo Line/Load
Regulation, and ripple and noise.
- 30 ~ +85°C
SWS100-12
0.99 / 0.95
10.8~13.2
13.8~16.2
Possible
79 / 81
TB1
20ms
8.9~
600
102
100
8.5
12
48
96
1.2 / 0.6
+V
-V
SWS100-15
13.5~16.5
17.2~20.3
81 / 83
100.5
7.0~
100
120
6.7
15
60
DENSEI-LAMBDA
Fig. A
A
SWS100-24
21.6~26.4
27.6~32.4
82 / 84
103.2
4.5~
150
144
4.3
24
96

Related parts for SWS10024

SWS10024 Summary of contents

Page 1

CA731-01-01B ITEMS 1 Nominal Output Voltage 2 Maximum Output Current 3 Maximum Output Power 4 Efficiency (Typ) 115/230VAC) 5 Input Voltage Range 6 Input Current (Typ) 115/230VAC) 7 Inrush Current (Typ) 8 PFHC 9 Power Factor (Typ) 115/230VAC) 10 Output ...

Page 2

CA731-01-02A SWS100-3,5,12,15,24 OUTPUT DERATING VS Ta CURVE (CONVECTION COOLING) 100 - Force Air Cooling : Recommended minimum air velocity is 1.2m/s, flow through the component side of power suppl SWS100-3,5,12,15,24 OUTPUT DERATING VS ...

Related keywords