LS50-12 TDK Corporation, LS50-12 Datasheet - Page 2

POWER SUPPLY 12V 4.2A SGL OUTPUT

LS50-12

Manufacturer Part Number
LS50-12
Description
POWER SUPPLY 12V 4.2A SGL OUTPUT
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS50-12

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
50W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 4.2A
Size / Dimension
3.9" L x 3.8" W x 1.4" H (99.1mm x 96.5mm x 35.6mm)
Power (watts) - Rated
50.4W
Operating Temperature
-25°C ~ 70°C
Efficiency
84%
Approvals
CE, EN, IEC, UL
Brand/series
LS Series
Configuration
Enclosed
Current, Output
4.2
Frequency, Input
47-63 Hz
Height
1.4 Inch
Length
3.9 Inch
Line Regulation
48 mV
Load Regulation
96 mV
Operation
Switching
Output
12 VDC @ 4.2 A
Power Rating
50 Watts
Power, Output
50.4 W
Primary Type
AC-DC
Ripple, Rejection
120 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
10.80-13.20
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
12 VDC
Weight
12.5 Ozs.
Width
3.8 Inch
Output Current (max)
4.2A
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1818
LS5012
1. Terminal Explanation
LS25, LS35, LS50, LS75
(1) L : Input terminal
(2) N : Input terminal
(3) FG
(4) - V : - Output terminal
(5) +V : + Output terminal
(6) Output voltage adjustable trimmer
(7) Output monitoring indicator (Green LED : ON)
LS100, LS150
(1) L : Input terminal
(2) N : Input terminal
(3) FG
(4) -V : - Output terminal
(5) +V : + Output terminal
(6) Output voltage adjustable trimmer
(7) Output monitoring indicator (Green LED : ON)
2. Terminal connecting method
Maximum output current of each output terminal is 25A except for LS25 (15A).
If more than 25A, use 2 terminals.
LOAD
( 25A max./ terminal)
( 25A max./ terminal)
Input must be off when making connection.
Connect FG terminal to ground terminal of the equipment.
The output load line and input line shall be separated and twisted to improve noise immunity.
-
+
LS25, LS35, LS50, LS75
: Functional Ground
: Functional Ground
Live line (Fuse in line)
Live line(Fuse in line)
Neutral line
Neutral line
1
LOAD
-
+
LS100, LS150
LS
INSTRUCTION MANUAL
TDK-Lambda
25-150
Series
1
2
3
4
5
1
2
3
4
5
6
7

Related parts for LS50-12