NH020F Lineage Power, NH020F Datasheet

no-image

NH020F

Manufacturer Part Number
NH020F
Description
CONVERTER DC/DC 3.3V 20W OUT
Manufacturer
Lineage Power
Series
NH020r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of NH020F

Output
3.3V
Number Of Outputs
1
Power (watts)
20W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
9-SIP Module
1st Output
3.3 VDC @ 6A
Size / Dimension
2.50" L x 0.24" W x 0.55" H (63.5mm x 6.1mm x 14mm)
Power (watts) - Rated
20W
Operating Temperature
0°C ~ 115°C
Efficiency
86%
Approvals
CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NH020F
Manufacturer:
LUCENT
Quantity:
103
Part Number:
NH020F
Manufacturer:
LUCENT
Quantity:
20 000
Data Sheet
March 28, 2008
Description
The NH020-Series Power SIPs are nonisolated dc-dc converters that operate over an input voltage range of 4.5 Vdc to 5.5
Vdc and provide a precisely regulated dc output. The SIPs have a maximum output current rating of 6 A at a typical full-load
efficiency of 86%. Standard features include remote on/off and output voltage adjustment.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Association.
Applications
n
n
n
Options
n
n
Distributed Power Architectures
Communication Equipment
Computer Equipment
Tight Tolerance output
-40 °C operation
RoHS Compliant
5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W
Features
n
n
n
n
n
n
n
n
n
n
n
Compatible with RoHS EU Directive 200295/EC
Compatible in Pb- free or SnPb reflow environment
Nonisolated output
High efficiency: 86% typical
Small size and low profile:
Remote On/Off
Output overcurrent protection
Output voltage adjustment
Overtemperature protection
UL* 60950 Recognized, CSA
Meets FCC classA radiated limits
63.5 mm x 5.6 mm x 14 mm
(2.5 in x 0.22 in x 0.55 in)
fied, and VDE
PDF Name:DS00-128EPS (Replaces DS00-127EPS)
NH020-Series Power SIPs:
0805 (IEC60950, 3rd edition) Licensed
C22.2 No. 60950-00 Certi-
Document Name:

Related parts for NH020F

NH020F Summary of contents

Page 1

Data Sheet March 28, 2008 RoHS Compliant Applications Distributed Power Architectures n Communication Equipment n Computer Equipment n Options Tight Tolerance output n -40 °C operation n Description The NH020-Series Power SIPs are nonisolated dc-dc converters that operate over an ...

Page 2

... A (see Safety Considerations section). To aid in the proper fuse selection for the given appli- cation, information on inrush energy and maximum dc input current is provided. Refer to the fuse manufacturer’s data for fur- ther information. Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output ...

Page 3

... Y — — All — — All — 0 All IO 0 All IO — NH020M h 70 NH020Y h 73 NH020G h 79 NH020F h 84 All — — All — — All — — All — — All — — Min Typ 1,400,000 — — Typ Max Unit 1 ...

Page 4

... Lineage Power 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Device Symbol All Von/off All Ion/off All Von/off All Ion/off All — NH020M Vtrim NH020Y Vtrim NH020G Vtrim NH020F Vtrim All TQ31 NH020-Series Power SIPs: Min Typ Max Unit –0.7 0 µA 6 1.5 5.0 ms 100 — ...

Page 5

... Typical Input Characteristics output current. Figure 2. Typical Output Characteristics. Figure 3. Typical Efficiency for NH020M . Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Figure 4. Typical Efficiency for NH020Y. Figure 5. Typical Efficiency for NH020A0G. Figure 6. Typical Efficiency for NH020F. 5 ...

Page 6

... Typical Output Ripple Voltage for NH020Y (6A Output Current). Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Figure 9. Typical Output Ripple Voltage for NH020F,G (6A Output Current). Figure 10. Typical Transient response to Step load change from 0% to 100% of I0,max at 5V Input . 6 ...

Page 7

... I0,max at 5V Input .(Waveform Averaged to remove ripple) Figure 12. Typical start up Transient at 5V input and 6A output. Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Figure 13. Typical start -up Transient with remote on/off at 5V Input and 6A output. ...

Page 8

... V V – I(+) I(-) Lineage Power 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Design Considerations Input Source Impedance The power SIP should be connected to a low ac- impedance input source. Highly inductive source impedances can affect the stability of the SIP. Adding external capacitance close to ...

Page 9

... ELV. The input to these units provided with a maximum 10A normal-blow fuse in the unearthed lead input electrolytic capacitor used, it should be selected using the design information found in the Design Considerations section. Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output ...

Page 10

... TRIM pin and either the VO pin (decrease output voltage) or GND pin (increase output volt- age). The trim range for the NH020F is +10%, –16%. The trim range for the NH020G is ±10% of VO, nom. The trim range for SIPs that produce less than 2 +20%, –0%. ...

Page 11

... Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Figure 26. NH020F Rtrim-up Test Results Overcurrent Protection To provide protection in a fault condition, the unit is equipped with internal overcurrent protection. The unit operates nor- mally once the fault condition is removed. ...

Page 12

... To predict the approximate cooling needed for the SIP, deter- mine the power dissipated as heat by the unit for the particu- lar application. Figures 29—32 show typical heat dissipation for the SIP over a range of output currents. Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Figure 29. ...

Page 13

... Data Sheet March 28, 2008 Figure 32. NH020F Power Dissipation vs. Output Current. With the known heat dissipation and a given local ambient temperature, the minimum airflow can be chosen from the derating curves in Figure 33. Figure 33. Power Derating vs. Local Ambient Temperature and Air Velocity For example, if the unit dissipates 2 heat, the mini- mum airflow ° ...

Page 14

... J-STD-001B. These requirements state that solder balls must neither be loose nor violate the power module minimum electrical spacing. The cleanliness designator of the open frame power module is C00 (per J specification). Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output ...

Page 15

... Outline Diagram for Through-Hole Module Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in. ± 0.010 in.) Front View Side View Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Pin Function 1 VO ...

Page 16

... Data Sheet March 28, 2008 Recommended Hole Pattern Component-side footprint. Dimensions are in millimeters and (inches). Note: No copper should be placed between pins 2 and 3 and pins 7 and 8. Lineage Power NH020-Series Power SIPs: 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output ...

Page 17

... PDF Name:DS00-128EPS (Replaces DS00-127EPS) 5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output Output Current Device Code 9 W NH020M 10.8 W NH020Y 15 W NH020G 20 W NH020F 20W NH020FZ 15 W NH020GZ 10.8 W NH020Y2Z Suffix sia-Pacific Head qu art ers T el: + 4283 dle-East an d Afric arters T el: + 6089 286 ...

Related keywords