Description
CONV DC/DC 12V 5A ADJ OUT SMD
Manufacturer
Bourns Inc.
Series
MX(T)r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of MX5A-12SA

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
27W
Mounting Type
Surface Mount
Voltage - Input
10 ~ 14V
Package / Case
5-DIP SMD Module
1st Output
0.75 ~ 5.5 VDC @ 5A
Size / Dimension
0.80" L x 0.45" W x 0.23" H (20.3mm x 11.4mm x 5.8mm)
Power (watts) - Rated
27.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
92%
Output Power
28 W
Input Voltage Range
10 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.75 V to 5.5 V
Output Current (channel 1)
5 A
Output Type
Adjustable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
 Details
Other names
MX5A-12SA-TR
MX5A-12SA-TR
MX5A-12SATR
Bourns
offering designers a cost and space-efficient solution with
standard features such as remote on/off, precisely regulated
programmable output voltage and overcurrent and over-
temperature protection. These modules deliver up to 5 A of
output current with load efficiency of 92 % at 5 V output.
Stress in excess of absolute maximum ratings may cause permanent damage to the device. Device reliability may be affected if
exposed to absolute maximum ratings for extended time periods.
Unless otherwise specified, specifications apply over all input voltage, resistive load and temperature conditions.
Caution: The power modules are not internally fused. An external input line fast-blow fuse with a maximum rating of 6 A is required.
See the Safety Considerations section of this data sheet.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify device performance in their specific applications.
Description
Absolute Maximum Ratings
Characteristic
Continuous Input Voltage
Operating Temperature Range
Storage Temperature
Electrical Specifications
Characteristic
Operating Input Voltage
Maximum Input Current
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current
Input Ripple Rejection
Applications
Intermediate Bus architecture
Distributed power applications
Workstations and servers
®
MX5A-12SA is a non-isolated DC-DC converter
Telecom equipment
Enterprise networks including LANs/WANs
Latest generation ICs (DSP, FPGA, ASIC) and microprocessor powered applications
MX5A-12SA SMT Non-Isolated Power Module
Features
Industry standard surface mount device
RoHS compliant*
Output voltage programmable from
0.75 V dc to 5.0 V dc via external resistor
Up to 5 A output current
Up to 92 % efficiency
Small size, low profile
Min.
Min.
10.0
-0.3
-40
-55
-
Nom.
Max.
+125
15.0
+85
1.6
26
70
40
30
Configuration
Internal Identifier
Output Current (Amps)
Input Voltage (V)
Outputs
Output Voltage (V)
Fixed output voltage parts and optional features available; contact factory.
Units
Max.
How to Order
14.0
V dc
• M = Surface Mount Device
3.5
0.4
°C
°C
• S = Single
• A = Adjustable
mAp-p
Units
V dc
A dc
A 2 s
mA
mA
mA
dB
See Thermal Considerations section
Over V in range, I o max, V out = 5 V dc
V in = 12 V dc , I o = 0 A, mod. enabled,
-V out = 0.75 V dc
-V out = 5.0 V dc
V in = 5.0 V dc , module disabled
120 Hz
Cost-efficient open frame design
Low output ripple and noise
High reliability
Remote on/off
Output overcurrent protection
(non-latching)
Constant switching frequency (300 kHz)
Wide operating temperature range
Notes & Conditions
Notes & Conditions
M X 5A - 12 S A
1

Related parts for MX5A-12SA

MX5A-12SA Summary of contents

Page 1

... Description ® Bourns MX5A-12SA is a non-isolated DC-DC converter offering designers a cost and space-efficient solution with standard features such as remote on/off, precisely regulated programmable output voltage and overcurrent and over- temperature protection. These modules deliver output current with load efficiency output. Absolute Maximum Ratings Stress in excess of absolute maximum ratings may cause permanent damage to the device ...

Page 2

... MX5A-12SA SMT Non-Isolated Power Module Electrical Specifications (Continued) Characteristic Output Voltage Setpoint Accuracy Output Voltage Tolerance Voltage Adjustment Range Line Regulation Load Regulation Temperature Regulation Output Current Output Current Limit Inception (Hiccup Mode) Output Short Circuit Current Output Ripple and Noise Voltage ...

Page 3

... MX5A-12SA SMT Non-Isolated Power Module Feature Specifications Characteristic Remote Enable Open = On (Logic Low) Low = Off (Logic High) Turn-On Delay and Rise Times Case 1: On/Off Low – Applied Case Applied, then On/Off Set Low Case 3: Output Voltage Rise Output Voltage Overshoot Overtemperature Protection ...

Page 4

... MX5A-12SA SMT Non-Isolated Power Module Characteristic Curves The curves provided below are typical characteristics for the MX5A-12SA modules at 25 °C. For any specific test configurations or any specific test requests, please contact Bourns. 100.0 95.0 90.0 85.0 80.0 75.0 70.0 1.0 2.0 3 ...

Page 5

... MX5A-12SA SMT Non-Isolated Power Module Characteristic Curves (Continued) 6.00 4.00 2.00 0.00 6.00 8.00 Input Voltage (V ) Fig. 7 Input Voltage vs. I and 2 6 Full Load: 10 mVolt 2.5 µs No Load: 10 mVolt 2.5 µs Half Load: 10 mVolt 2.5 µs µ Time (2.5 s/div) Fig. 8 Typical Output Ripple and Noise ( ...

Page 6

... MX5A-12SA SMT Non-Isolated Power Module Characteristic Curves (Continued) Output Voltage: 100 mVolt 10 µs Output Current (0.9 A/Div): 2 Volt 10 µ Time (5 µs/div) Fig. 13 Transient Response - 2.5 A Step ( 3 ext ?? Output Voltage: 1 Volt 1 ms On/Off Voltage: 5 Volt 1 ms Time (1 ms/div) Fig. 14 Typical Start-up using Positive Remote On/Off ( ...

Page 7

... MX5A-12SA SMT Non-Isolated Power Module Characteristic Curves (Continued) 6 200 LFM 5 0 LFM 4 100 LFM Ambient Temperature (°C) Fig. 19 Derating Output Current vs. Local Ambient Temp. and Airflow ( 200 LFM 6 0 LFM 5 100 LFM Ambient Temperature (°C) Fig. 20 Derating Output Current vs. ...

Page 8

... Remote On/Off The MX5A-12SA comes standard with Active LOW with Negative On/Off logic, i.e., OPEN or LOW (< 0.4 V) will turn ON the device. To turn the device OFF, increase the voltage level above 2.4 V, placing the part into low dissipation sleep mode. The signal level of the On/Off pin input is defined with respect to ground ...

Page 9

... If left open circuit the output voltage will default to 0.75 Vdc. The correct Rtrim value for a specific voltage can be calculated using the following equation: Rtrim = [10.5/(Vo-0.7525)-1] KΩ For example, to set the MX5A-12SA to 3.3 V the following Rtrim resistor must be used: Rtrim = [10.5/(3.3-0.7525)-1] KΩ ...

Page 10

... MX5A-12SA SMT Non-Isolated Power Module Operating Information (Continued) Voltage Margining Output voltage margining can be implemented as follows: 1) Trim-up: Connect a resistor, Rm-up, from the Trim pin to the ground pin for adjusting the voltage upwards, and 2) Trim-down: Connect a resistor, Rm-down, from the Trim pin to the output pin for adjusting the voltage downwards. ...

Page 11

... Coplanarity The MX5A-12SA device has a maximum coplanarity of 100 µm (approx. 0.004 ”), as defined by JESD22-B108. Pin Plating Composition Tin (Sn) plating over nickel (Ni). Recommended Pad Layout Specifications are subject to change without notice. Customers should verify device performance in their specific applications. ...

Page 12

... MX5A-12SA SMT Non-Isolated Power Module Use in Manufacturing Environment Pick and Place Information Bourns SMT devices, packaged on tape and reel, are designed (low mass) for automated assembly using standard SMT pick and place equipment. The centrally located inductor provides the flat surface area to be used for component pick up. Variables such as nozzle style, nozzle size, handling speed, and placement pressure need to be optimized for best results ...

Page 13

... MX5A-12SA SMT Non-Isolated Power Module Use in Manufacturing Environment (Continued) Soldering Requirements Bourns recommends the following temperature profile for use on tin lead solder (Sn-Pb Eutectic) and lead free solder. For lead free solder, the maximum temperature during the mounting process should not exceed 245 °C. Sufficient time must be allowed to fuse the plating on the connection to ensure a reliable solder joint. However, the time above 230 ° ...

Related keywords