ATA010A0X3 Lineage Power, ATA010A0X3 Datasheet
ATA010A0X3
Specifications of ATA010A0X3
Available stocks
Related parts for ATA010A0X3
ATA010A0X3 Summary of contents
Page 1
Data Sheet October 1, 2009 Austin Lynx 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A Output Current RoHS Compliant EZ-SEQUENCE Applications Distributed power architectures Intermediate bus voltage applications Telecommunications equipment Servers and storage applications Networking equipment Enterprise Networks Latest ...
Page 2
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, ...
Page 3
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Electrical Specifications (continued) Parameter Output Voltage Set-point ( =25°C) IN IN, min O O, max A Output Voltage ...
Page 4
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Electrical Specifications (continued) Parameter Dynamic Load Response (dIo/dt=2.5A/μ =25°C) IN IN, nom A Load Change from Io= 50% ...
Page 5
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter ...
Page 6
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Characteristic Curves The following figures provide typical characteristics for the Austin Lynx ...
Page 7
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Characteristic Curves (continued) The following figures provide typical characteristics for the Austin Lynx ...
Page 8
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Characteristic Curves (continued) The following figures provide typical characteristics for the Austin Lynx TIME, t (10μs/div) Figure 13. Transient Response to Dynamic Load Change ...
Page 9
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Characteristic Curves (continued) The following figures provide thermal derating curves for the Austin Lynx 100 LFM ...
Page 10
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Test Configurations TO OSCILLOSCOPE L TEST 1μ 1000μF S Electrolytic 2x100μF E.S.R.<0.1Ω Tantalum @ 20°C 100kHz NOTE: Measure input reflected ripple ...
Page 11
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Design Considerations (continued) Output Filtering TM The Austin Lynx II SIP module is designed for low output ripple voltage and will meet the maximum ...
Page 12
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Feature Description Remote On/Off TM The Austin Lynx II SMT power modules feature an On/Off pin for remote On/Off operation. Two On/Off logic options ...
Page 13
... The POL ⎤ Programming Tool, available at ⎥ under the Design Tools section, also calculates the ⎦ values of R margin-up voltage and % margin. Please consult your local Lineage Power technical representative for additional details. LOAD Austin Lynx or Lynx II Series R trim Open 22.46 Figure 30 ...
Page 14
... When pre-bias immunity during start- required, the EZ-SEQUENCE feature must be disabled. For additional guidelines on using EZ- TM SEQUENCE feature of Austin Lynx Lineage Power technical representative for preliminary application note on output voltage sequencing using Austin Lynx II series. LINEAGE POWER TM Austin Lynx II 12V SIP Non-isolated Power Modules: ...
Page 15
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations ...
Page 16
... Pb-free solder pot is 270°C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power technical representative for more details. LINEAGE POWER TM ...
Page 17
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Mechanical Outline Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ...
Page 18
Data Sheet October 1, 2009 8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx ...
Page 19
... Table 2. Device Codes Input Voltage Device Code Range ATA010A0X3 8.3 – 14Vdc ATA010A0X43 8.3 – 14Vdc ATA010A0X3Z 8.3 – 14Vdc ATA010A0X43Z 8.3 – 14Vdc -Z refers to RoHS compliant codes World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U ...