AXH010A0X3 Lineage Power, AXH010A0X3 Datasheet - Page 2

no-image

AXH010A0X3

Manufacturer Part Number
AXH010A0X3
Description
CONVE DC/DC 0.75 3.63V @ 10A SIP
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXH010A0X3

Rohs Status
RoHS non-compliant
Output
0.75 ~ 3.63V
Number Of Outputs
1
Power (watts)
36W
Mounting Type
Through Hole
Voltage - Input
3 ~ 5.5V
Package / Case
10-SIP Module
1st Output
0.75 ~ 3.63 VDC @ 10A
Size / Dimension
2.00" L x 0.32" W x 0.50" H (50.8mm x 8.1mm x 12.7mm)
Power (watts) - Rated
36W
Operating Temperature
-40°C ~ 85°C
Efficiency
95%
Approvals
CSA, EN, UL, VDE
3rd Output
-
2nd Output
-
Other names
555-1015

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AXH010A0X3
Manufacturer:
EMERSON
Quantity:
1 000
Data Sheet
December 1, 2010
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a 15A,
time-delay fuse (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.
LINEAGE
Parameter
Input Voltage
Operating Ambient Temperature
Storage Temperature
Parameter
Operating Input Voltage
Maximum Input Current
(V
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
V
Input Ripple Rejection (120Hz)
IN, max,
Continuous
(see Thermal Considerations section)
(V
(V
IN
= V
IN
IN
= 5.0Vdc, I
= 5.0Vdc, module disabled)
IN, min
I
O
= I
POWER
Omax
to V
; See Test configuration section)
IN, max
O
= 0, module enabled)
, I
O
=I
O, max
V
3.0Vdc – 5.5Vdc input; 0.75 to 3.63Vdc Output; 10A Output Current
O,set
Austin Lynx
= 3.3Vdc)
IN, min
to
V
V
TM
O,set
O,set
Device
SIP Non-isolated Power Modules, Programmable:
= 0.75Vdc
= 3.3Vdc
All
All
All
All
All
All
Device
All
All
All
Symbol
I
I
I
IN,stand-by
IN,No load
IN,No load
I
IN,max
V
I
Symbol
2
IN
t
T
V
T
stg
IN
A
Min
3.0
Min
-0.3
-40
-55
Typ
100
1.5
25
30
30
Max
125
5.8
85
Max
5.5
0.1
10
mAp-p
Unit
Vdc
°C
°C
Unit
Vdc
Adc
mA
mA
mA
A
dB
2
s
2

Related parts for AXH010A0X3