AXA010A0X3 Lineage Power, AXA010A0X3 Datasheet - Page 15

no-image

AXA010A0X3

Manufacturer Part Number
AXA010A0X3
Description
CONVER DC/DC 0.75 5.5V @ 10A SIP
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXA010A0X3

Rohs Status
RoHS non-compliant
Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
55W
Mounting Type
Through Hole
Voltage - Input
10 ~ 14V
Package / Case
10-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 10A
Size / Dimension
2.00" L x 0.32" W x 0.50" H (50.8mm x 8.1mm x 12.7mm)
Power (watts) - Rated
55W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
No RoHS Version Available
Other names
555-1013

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AXA010A0X3-SR
Manufacturer:
JAM
Quantity:
1 200
Part Number:
AXA010A0X3-SR
Manufacturer:
LINEAGEPO
Quantity:
20 000
Part Number:
AXA010A0X3-SRZ
Manufacturer:
SEC
Quantity:
3
Data Sheet
September 30, 2009
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 32. Note that the airflow is parallel to
the long axis of the module as shown in figure 31. The
derating data applies to airflow in either direction of the
module’s long axis.
Figure 31. T ref Temperature measurement location.
The thermal reference point, T
specifications is shown in Figure 31. For reliable
operation this temperature should not exceed 115
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Air Flow
POWER
Top View
12V Austin Lynx
10Vdc – 14Vdc input; 0.75Vdc to 5.5Vdc Output;10A Output Current
ref
used in the
T
TM
ref
o
C.
SIP Non-isolated Power Modules, Programmable:
Wind T unnel
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves
showing the maximum output current that can be
delivered at different local ambient temperature (T
airflow conditions ranging from natural convection and
up to 2m/s (400 ft./min) are shown in the Characteristics
Curves section.
PWBs
Figure 33. Thermal Test Set-up.
flow
Air
(0.325)
x
8.3_
(3.0)
76.2_
25.4_
(1.0)
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
A
) for
15

Related parts for AXA010A0X3