APXS003A0X-SRZ Lineage Power, APXS003A0X-SRZ Datasheet - Page 18

CONVERTER DC-DC 0.59 5.5V @ 3A

APXS003A0X-SRZ

Manufacturer Part Number
APXS003A0X-SRZ
Description
CONVERTER DC-DC 0.59 5.5V @ 3A
Manufacturer
Lineage Power
Series
Pico TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXS003A0X-SRZ

Output
0.59 ~ 5.5V
Number Of Outputs
1
Power (watts)
16W
Mounting Type
Surface Mount
Voltage - Input
4.5 ~ 14V
Package / Case
10-SMD Module
1st Output
0.59 ~ 5.5VDC @ 3A
Size / Dimension
0.48" L x 0.48" W x 0.25" H (12.2mm x 12.2mm x 6.3mm)
Power (watts) - Rated
16.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
92%
Approvals
CSA, EN, UL, VDE
Output Power
17 W
Input Voltage Range
4.5 V to 14 V
Output Voltage (channel 1)
0.59 V to 5.5 V
Output Current (channel 1)
3 A
Package / Case Size
12.2 mm x 12.2 mm x 6.25 mm
Output Type
Non-Isolated
Output Voltage
0.59 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1126-2
Data Sheet
November 22, 2010
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-
up is shown in Figure 49. The preferred airflow
direction for the module is in Figure 50.
The thermal reference points, T
specifications are also shown in Figure 50. For
reliable operation the temperatures at these points
should not exceed 120
module should not exceed the rated power of the
module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 49. Thermal Test Setup.
o
C. The output power of the
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
4.5 – 14Vdc input; 0.59Vdc to 5.5Vdc output; 3A output current
ref
used in the
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
12V Pico TLynx
TM
Figure 50. Preferred airflow direction and
locations of hot-spots of the module (Tref).
3A: Non-isolated DC-DC Power Modules
18

Related parts for APXS003A0X-SRZ