APTS012A0X3-SRZ Lineage Power, APTS012A0X3-SRZ Datasheet - Page 2

CONV DC-DC 0.69 5.5V @ 12A SMD

APTS012A0X3-SRZ

Manufacturer Part Number
APTS012A0X3-SRZ
Description
CONV DC-DC 0.69 5.5V @ 12A SMD
Manufacturer
Lineage Power
Series
Micro TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APTS012A0X3-SRZ

Output
0.69 ~ 5.5V
Number Of Outputs
1
Power (watts)
66W
Mounting Type
Surface Mount
Voltage - Input
4.5 ~ 14V
Package / Case
10-SMD Module
1st Output
0.69 ~ 5.5 VDC @ 12A
Size / Dimension
0.80" L x 0.45" W x 0.33" H (20.3mm x 11.4mm x 8.5mm)
Power (watts) - Rated
66W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
CSA, EN, UL, VDE
Output Power
66 W
Input Voltage Range
4.5 V to 14 V
Output Voltage (channel 1)
0.69 V to 5.5 V
Output Current (channel 1)
12 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
0.69 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1129-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APTS012A0X3-SRZ
Manufacturer:
LINEAGE
Quantity:
20 000
December 2, 2010
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 15A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
Parameter
Input Voltage
Voltage on SEQ terminal
Voltage on SYNC terminal
Voltage on PG terminal
Operating Ambient Temperature
Storage Temperature
Parameter
Operating Input Voltage
Maximum Input Current
(V
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
14V
Input Ripple Rejection (120Hz)
Continuous
(see Thermal Considerations section)
(V
(V
(V
IN
=4.5V to 14V, I
,
IN
IN
IN
I
O
= 10.0Vdc, I
= 12.0Vdc, I
= 12.0Vdc, module disabled)
= I
Omax
POWER
; See Test Configurations)
O
O
O
=I
= 0, module enabled)
= 0, module enabled)
O, max
)
4.5 – 14Vdc input; 0.69Vdc to 5.5Vdc output; 12A output current
IN
=0 to
V
V
O,set
O,set
Device
= 0.69 Vdc
= 3.3Vdc
All
All
All
All
All
All
-D version
Device
All
All
All
All
All
All
Symbol
I
I
I
IN,stand-by
IN,No load
IN,No load
I
IN,max
V
I
Symbol
2
IN
t
V
V
V
T
V
SYNC
T
T
SEQ
PG
stg
IN
A
A
Min
4.5
Min
-0.3
-0.3
-0.3
-0.3
-40
-40
-55
Typ
1.2
26
60
70
45
Max
105
125
V
15
12
85
6
IN
Max
14.0
11.5
1
mAp-p
dB
Unit
Vdc
Vdc
Vdc
Vdc
°C
°C
°C
Unit
Vdc
Adc
mA
mA
mA
A
2
s
2

Related parts for APTS012A0X3-SRZ