IPM24S0B0S03FA Delta Electronics, IPM24S0B0S03FA Datasheet

no-image

IPM24S0B0S03FA

Manufacturer Part Number
IPM24S0B0S03FA
Description
POWER MOD DC/DC 3.3~6.5V@3A 20W
Manufacturer
Delta Electronics
Series
DELPHIr
Type
Point of Load (POL) Non-Isolated with Remote On/Off and UVLOr

Specifications of IPM24S0B0S03FA

Output
3.3 ~ 6.5V
Number Of Outputs
1
Power (watts)
20W
Mounting Type
Surface Mount
Voltage - Input
11 ~ 36V
Package / Case
7-SMD Module
1st Output
3.3 ~ 6.5 VDC @ 3A
Size / Dimension
0.70" L x 0.59" W x 0.31" H (17.8mm x 15mm x 7.8mm)
Power (watts) - Rated
20W
Operating Temperature
-40°C ~ 125°C
Efficiency
91%
Approvals
CE, cUL, TUV, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Other names
941-1010-2
IPM24S0B0S03A
IPM24S0B0S03A
IPM24S0B0S03FA
Q4884455A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IPM24S0B0S03FA
Manufacturer:
EXAR
Quantity:
101
Part Number:
IPM24S0B0S03FA
Manufacturer:
DELTA
Quantity:
10
Evaluation Procedure
EP_IPM24S_07312006
Evaluation Procedure
(DEP-003)
The IPM24S Series POL
converters
The IPM Series, single output, non-isolated
point of load DC/DC converters, are the latest
offering from a world leader in power systems
technology and manufacturing ― Delta
Electronics, Inc. They operate from an
8V~36V
(IPM24S0B0) or an 20~36V(IPM24S0C0)
source and provide a programmable output
voltage of 1.2V to 2.5V(IPM24S0A0) or 3.3V
to 6.5V (IPM24S0B0) or 8.0V to 15.0V
(IPM24S0C0).
technology and optimization of component
placement,
outstanding
performance, as well as offering extremely
high reliability under highly stressful operating
conditions. All models are protected against
abnormal input/output voltage and current
conditions.
This document guides the user through the
evaluation procedures to qualify a POL
module. The data shown in this Evaluation
Procedure is for both SIP and SMT Package
Type POL evaluation board. Please refer to
the appropriate technical data sheet for
detailed performance and technical information
for the specific POL units.
(IPM24S0A0)
these
electrical
With
converters
or
creative
and
an
11V~36V
possess
thermal
design
1
IPM24S Series
1.0 Purpose
This document guides the user in performing
electronic measurements on an IPM24S POL
(point of load) DC/DC converter using the Delta
IPM24S Evaluation Board.
2.0 Relevant Documentation
The documentation and background information
listed below are relevant to this evaluation
procedure:
․ Applicative date sheet for IPM24S Series unit
․ Power Module Evaluation Board Schematic.
․ Power Module Evaluation Board Layout.
․ General Test and Safety Procedures.
under evaluation.
Delta Electronics, Inc.

Related parts for IPM24S0B0S03FA

IPM24S0B0S03FA Summary of contents

Page 1

... The documentation and background information listed below are relevant to this evaluation procedure: ․ Applicative date sheet for IPM24S Series unit under evaluation. ․ Power Module Evaluation Board Schematic. ․ Power Module Evaluation Board Layout. ․ General Test and Safety Procedures. 1 Delta Electronics, Inc. ...

Page 2

Equipment Required ․ DC Power Supply (Agilent 6574A 0 -60V/0 - 35A or equivalent). ․Oscilloscope (Tektronix TDS 460A or equivalent) 4 Channel 400 MHz, equipped with a x1 scope probe, a ...

Page 3

Connect one lead from the “+” lead of the power supply to the “20A” terminal of the first multimeter DMM1. Then connect one lead from the “Common” of the DMM1 to the “Vin+” pin of the Evaluation Board. Set ...

Page 4

Tests Performed The following tests are performed at room temperature (+25 C). 6.1 Input Characteristics Input Voltage Range. Under-Voltage Locko No Load Input Current 6.2 O utput Characteristics Line Regulation. Load Regulation. Output Regulation . Output Voltage Se t-point ...

Page 5

SW3 for the trim-down or trim-up setting of the Output Voltage. For IPM, if the converter requires a trim up, set SW3 to the Trim-up position. If the converter requires a trim down, set SW3 to ...

Page 6

Initial Power Up 1) Turn the power supply ON, set the current limit on power supply (refer to specification of either converter) and in reaches the desired value. 2) Set the switch SW1 to “ON” position to enable the ...

Page 7

Output Characteristics 8.2.1 Line Regulation Line Regulation Deviation is defined as the change in output voltage caused by varying the in put voltage over ...

Page 8

Output Voltage Set-Point Adjustment Range (Trim) Output Voltage Set-Point Adjustment can be carried out by using an external resistor or external voltage source to increase or decrease the output voltag th e data sheet for the detailed specification). Refer ...

Page 9

Rtrim values versus some commonly used Vout for IPM24S0B0R03 A. Vo Vadj Vadj Vadj Vadj 3.3*(1-10%) Rtrim values versus some commonly used Vout for IPM24S0C0R03 A. Vo Vadj Vadj 8.0*(1-10%) Test T 1) urn on the fan. 2) Adjust the ...

Page 10

Turn-On Transient Time Turn-On Response Time is defined as the time it takes for the output to rise to within 90% of its final value from the time when the converter is enabled. The rise time is deliberately made ...

Page 11

Thermal Characteristic 8.4.1 Efficiency Efficiency is the ratio of total output power to the input power typically measured at full load and nominal input voltage. Test 1) Turn on the fan. 2) Set the enable switch SW1 ...

Page 12

Appendix A- Evaluation Board Schematic 14 ...

Page 13

Appendix B - Evaluation Board Layout (Top View) 15 ...

Page 14

Appendix C - Evaluation Board Layout (Bottom View) CONTACT: www.delta.com.tw/dcdc USA: Telephone: East Coast: (888) 335 8201 West Coast: (888) 335 8208 Fax: (978) 656 3964 Email: DCDC@delta-corp.com WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information ...

Related keywords