CONVERTER DC/DC 5-15V 70W SIP

AXB070X43Z

Manufacturer Part Number
AXB070X43Z
Description
CONVERTER DC/DC 5-15V 70W SIP
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXB070X43Z

Output
5 ~ 15V
Number Of Outputs
1
Power (watts)
70W
Mounting Type
Through Hole
Voltage - Input
20 ~ 30V
Package / Case
10-SIP Module
1st Output
5 ~ 15 VDC @ 4.5A
Size / Dimension
2.00" L x 0.32" W x 0.50" H (50.8mm x 8.1mm x 12.7mm)
Power (watts) - Rated
70W
Operating Temperature
-40°C ~ 85°C
Efficiency
97%
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
Output Power
70 W
Input Voltage Range
20 V to 30 V
Output Voltage (channel 1)
5 V to 15 V
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
5 V to 15 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1153
CC109121480
Test Configurations
Figure 25. Input Reflected Ripple Current Test
Setup.
Figure 26. Output Ripple and Noise Test Setup.
Figure 27. Output Voltage and Efficiency Test Setup.
NOTE: All voltage measurements to be taken at the module
Data Sheet
October 2, 2009
LINEAGE
V
GND
O
(+)
Efficiency
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
TO OSCILLOSCOPE
NOTE: Measure input reflected ripple current with a simulated
R
R
NOTE: All voltage measurements to be taken at the module
distribution
distribution
0.01uF
source inductance (L
possible battery impedance. Measure current as shown
above.
POWER
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
COPPER STRIP
R
R
contact
contact
η =
0.1uF
@ 20°C 100kHz
E.S.R.<0.1Ω
C
S
GROUND PLANE
10uF
L
220μF
V
1μH
TEST
IN
V
V
V
COM
IN
IN
O
TEST
(+)
. I
. I
) of 1μH. Capacitor C
O
IN
SCOPE
COM
V
O
V
150μF
C
x 100 %
O
Min
IN
RESISTIVE
LOAD
CURRENT PROBE
R
R
contact
contact
S
offsets
V
COM
IN
(+)
R
R
distribution
distribution
R
LOAD
Austin Lynx
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards,
i.e., UL 60950, CSA C22.2 No. 60950-00, EN60950
(VDE 0850) (IEC60950, 3
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.