OKX2-T/16-W5N-C Murata Power Solutions Inc, OKX2-T/16-W5N-C Datasheet - Page 5

CONV DC/DC SIP 52.8W .75-3.6VOUT

OKX2-T/16-W5N-C

Manufacturer Part Number
OKX2-T/16-W5N-C
Description
CONV DC/DC SIP 52.8W .75-3.6VOUT
Manufacturer
Murata Power Solutions Inc
Series
Okami™ OKX-T/16-W5r
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of OKX2-T/16-W5N-C

Number Of Outputs
1
Package / Case
11-SIP Module
Output
0.75 ~ 3.63V
Power (watts)
52W
Mounting Type
Through Hole
Voltage - Input
2.4 ~ 5.5V
1st Output
0.75 ~ 3.63 VDC @ 16A
Size / Dimension
2.00" L x 0.37" W x 0.50" H (50.8mm x 9.4mm x 12.7mm)
Power (watts) - Rated
52.8W
Operating Temperature
-40°C ~ 85°C
Efficiency
95%
Approvals
EN, IEC, UL
Output Power
52.8 W
Input Voltage Range
2.4 V to 5.5 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
0.7525 V to 3.63 V
Output Current (channel 1)
16 A
Package / Case Size
SIP
Output Voltage
0.7525 V to 3.63 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-2151-5
See Note 1
Input Voltage Range
Start-Up Voltage
Undervoltage Shutdown (see Note 15)
Overvoltage Shutdown
Refl ected (Back) Ripple Current (Note 2) 20 mA pk-pk
Internal Input Filter Type
Recommended External Fuse
Reverse Polarity Protection
Input Current:
Remote On/Off Control (Note 5)
Tracking/Sequencing (OKX “2” models)
Effi ciency
Switching Frequency
Start-Up Time (Vin on to Vout regulated) 8 mSec for Vout=nominal
Isolation
Safety
Calculated MTBF per Telcordia SR-232 (4a) TBC
Calculated MTBF per MIL-HDBK-217F (4b) TBC
Minimum Loading
Accuracy (50% load, untrimmed)
Voltage Output Range (Note 13)
Overvoltage Protection (Note 16)
Temperature Coeffi cient
Ripple/Noise (20 MHz bandwidth)
Line/Load Regulation
Maximum Capacitive Loading (Note 14)
Current Limit Inception (Note 6)
Short Circuit Mode
Full Load Conditions
Inrush Transient
Shutdown Mode (Off, UV, OT)
Output in Short Circuit
No Load
Low Line (Vin=Vmin, Vout=Vnom)
Negative Logic (“N” model suffi x)
Positive Logic (“P” model suffi x)
Current
Slew Rate
Tracking accuracy, rising input
Tracking accuracy, falling input
(98% of Vout setting, after warm up)
Short Circuit Current Output
Protection Method
Short Circuit Duration
(On/Off to Vout regulated)
Cap-ESR=0.001 to 0.01 Ohms
Cap-ESR >0.01 Ohms
See Ordering Guide and Note 7.
2.05V
1.90V
None
Capacitive
15A fast blow
N/A. See fuse information
See Ordering Guide
0.4 A
5 mA
60 mA
80 mA
9.05A (T/10), 14.63A (T/16)
ON = Open pin or ground to +0.4V. max.
OFF =+1.5V min. to + Vin (max)
ON = Open pin (internally pulled up) or
+1.5V to +Vin max.
OFF = Ground pin to +0.4V. max.
1 mA max.
2 Volts per millisecond, max.
Vout = ±200 mV max. of Sequence In
Vout = ±400 mV max. of Sequence In
See Ordering Guide
300 KHz
6 mSec for Vout=nominal
Not isolated
Certifi ed to UL/cUL 60950-1,
CSA-C22.2 No. 60950-1, IEC/EN 60950-1
No minimum load
±2 % of Vnominal
See Ordering Guide
None
±0.02% per °C of Vout range
See Ordering Guide and note 8
See Ordering Guide and note 10
1,000 μF
5,000 μF (min. cap. load 0 μF )
34 Amps (OKX2-T/16-W5)
29 Amps (OKX2-T/10-W5)
1 A
Hiccup autorecovery upon overload
removal. (Note 7)
Continuous, no damage
(output shorted to ground)
2
Sec.
www.murata-ps.com
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Absolute maximums are stress ratings. Exposure of devices to greater than any of any
of these conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifi cations Table is
not implied nor recommended.
(1)
(2)
(3)
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ISSUE 2,
(4b) Mean Time Before Failure is calculated using MIL-HDBK-217F, GB ground benign, Tambient=+25 deg.C, full
(5)
(6)
(7)
(8)
Prebias Startup
Dynamic Load Response
Operating Temperature Range (Ambient)
Operating PC Board Temperature
Storage Temperature Range
Thermal Protection/Shutdown
Relative Humidity
Outline Dimensions
Weight
Restriction of Hazardous Substances
Input Voltage (Continuous or transient)
On/Off Control
Input Reverse Polarity Protection
Output Current (Note 7)
Storage Temperature
Lead Temperature
Specifications are typical at +25 deg.C, Vin=nominal (+5V.), Vout=nominal (+3.3V), full load, external caps
and natural convection unless otherwise indicated. Extended tests at higher power must supply substantial
forced airflow.
All models are tested and specified with external 1 μF paralleled with 10 μF ceramic output capacitors
and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary
to accommodate our test equipment and may not be required to achieve specified performance in your
applications. However, Murata Power Solutions recommends installation of these capacitors. All models are
stable and regulate within spec under no-load conditions.
Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is
Cin=2 x 100 μF tantalum, Cbus=1000 μF electrolytic, Lbus=1 μH.
Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
ground fixed controlled conditions, Tambient=+25 deg.C, full output load, natural air convection.
output load, natural air convection.
-Input Common. A logic gate may also be used by applying appropriate external voltages which not exceed
+Vin.
Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected
setting.
“Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output.
If the overcurrent condition still exists, the restart current will be removed and then tried again. This short
current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter
immediately recovers normal operation.
Output noise may be further reduced by adding an external filter. At zero output current, the output may
contain low frequency components which exceed the ripple specification. The output may be operated
indefinitely with no load.
(50-100% load step, di/dt=2.5A/μSec) with 2 x 150 μF polymer external caps.
See derating curves
The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to
Converter will start up if the external
output voltage is less than Vset
100 μSec max. to within ±2% of fi nal value
-40 to +85 deg. C. with derating (Note 9)
-40 to +100 deg. Celsius max.,
no derating (12)
-55 to +125 deg. C.
+130 deg. Celsius
to 85%RH/+85 deg. C., non-condensing
See Mechanical Specifi cations
0.2 ounces (5.6 grams)
RoHS-6 (does not claim EU RoHS
exemption 7b–lead in solder)
0 V.to +5.8 Volts max.
0 V. min. to +Vin max.
See Fuse section
Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
-55 to +125 deg. C.
See soldering specifi cations
Page 5 of 13

Related parts for OKX2-T/16-W5N-C