Specifications of VPOL15A-5-SIP

Output
0.9 ~ 3.63V
Number Of Outputs
1
Power (watts)
54W
Mounting Type
Through Hole
Voltage - Input
3 ~ 5.5V
Package / Case
11-SIP Module (10 Leads)
1st Output
3.63 VDC @ 15A
Size / Dimension
2.00" L x 0.34" W x 0.50" H (50.8mm x 8.6mm x 12.7mm)
Power (watts) - Rated
54W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
cUL, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
Other names
102-1291
PART NUMBER: VPOL15A-5-SIP
7.2 Convection Requirements for Cooling
To predict the ap proximate cooling needed for the module, refer to the
Power De-rating curves in Figures 8 to 10 . These de-rating curves are
approximations of the ambient temperatures and airflows required to
keep the power module temperature below its maximum rating. Once the
module is assembled in the actual system, the module’s temperature
should be checked as shown in Figure 6 to ensure it does not exceed
110°C.
Proper cooling can be verified by measuring the power module’s
temperature at Q1-pin 6 and Q2-pin 6 as shown in Figure 7.
Tunnel
Bakelite
W ind
20050 SW 112
Note : Dimensions are in millimeters and (inches)
Figure 6. Thermal Test Setup
th
25.4(1.0)
Ave. Tualatin, Oregon 97062
12.7(0.5)
Air
flow
76.2(3.0)
Power Module
Thermocuple Location
for measuring
ambient temperature
and airflow
phone 503.612.2300 fax 503.612.2382
DESCRIPTION: point of load converter
7.3 Thermal Considerations
The power module operates in a variety of thermal
however, sufficient cooling should be provided to help ensure reliable
operation of the unit. Heat is removed by conduction, convection, and
radiation to the surrounding environment. The thermal data presented is
based on measurements taken in a set-up as shown in Figure 6. Figures
8 to 10 represent the test data. Note that the airflow is parallel to the long
axis of the module as shown in Figure 6 for the VPOL15A-5-SIP.
The temperature at either location should not exceed 110 °C. The output
power of the module should not exceed the rated power for the module
(VO, set x IO, max). The SMT15 thermal data presented is based on
measurements taken in a wind tunnel. The test setup shown in Fig 6 and
EUT need to solder on 33mm x 40.38mm(1.300'' x 1.59'') test pcb. Note
that airflow is parallel to the long axis of the module as shown in Fig 6.
Figure 7. Temperature Measurement Location for
Inductor Pin
VPOL15A-5-SIP
Airflow
environments;
rev.
page
date
Pin6
08/2007
7 of 12

Related parts for VPOL15A-5-SIP