JW150H1 Lineage Power, JW150H1 Datasheet - Page 14

no-image

JW150H1

Manufacturer Part Number
JW150H1
Description
CONVERTER DC/DC 24V 150W OUT
Manufacturer
Lineage Power
Series
JW150r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW150H1

Output
24V
Number Of Outputs
1
Power (watts)
150W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
24 VDC @ 6.2A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
150W
Operating Temperature
-40°C ~ 100°C
Efficiency
89%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW150H1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW150H1
Manufacturer:
LUCENT
Quantity:
560
Part Number:
JW150H1
Manufacturer:
LUCENT
Quantity:
20 000
Part Number:
JW150H1
Quantity:
55
Part Number:
JW150H1-150W
Manufacturer:
LUCENT
Quantity:
20 000
dc-dc Converters; 36 to 75 Vdc Input, 24 Vdc Output; 50 W to 175 W
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature (T
occurs at the position indicated in Figure 29.
Note: Top view, pin locations are for reference only.
Figure 29. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
For additional information on these modules, refer to
the Thermal Management JC-, JFC-, JW-, and JFW-
Series 50 W to 150 W Board-Mounted Power Modules
Technical Note
(TN97-008EPS).
14
14
Measurements shown in millimeters and (inches).
7.6 (0.3)
Location
V
ON/OFF
CASE
V
I
I
38.0 (1.50)
(+)
(–)
+ SEN
– SEN
V
V
TRIM
O
O
(–)
(+)
MEASURE CASE
TEMPERATURE HERE
8-716 (C).f
C
)
Heat Transfer Without Heat Sinks
Increasing airflow over the module enhances the heat
transfer via convection. Figure 30 shows the maximum
power that can be dissipated by the module without
exceeding the maximum case temperature versus local
ambient temperature (T
through 4 m/s (800 ft./min.).
Note that the natural convection condition was mea-
sured at 0.05 m/s to 0.1 m/s (10 ft./min. to 20 ft./min.);
however, systems in which these power modules may
be used typically generate natural convection airflow
rates of 0.3 m/s (60 ft./min.) due to other heat dissipat-
ing components in the system. The use of Figure 30 is
shown in the following example.
Example
What is the minimum airflow necessary for a JW100H
operating at V
maximum ambient temperature of 40 °C?
Solution
Given: V
Determine P
Determine airflow (v) (Use Figure 30):
Figure 30. Forced Convection Power Derating with
35
30
25
20
15
10
5
0
I
T
P
v = 1.0 m/s (200 ft./min.)
O
0
A
I
D
= 4.2 A
= 54 V
= 40 °C
= 12 W
No Heat Sink; Either Orientation
0.1 m/s (NAT. CONV.)
D
10
I
(Use Figure 33):
= 54 V, an output current of 4.2 A, and a
LOCAL AMBIENT TEMPERATURE, T
20
(20 ft./min.)
30
A
) for natural convection
40
50
60
4.0 m/s (800 ft./min.)
3.5 m/s (700 ft./min.)
3.0 m/s (600 ft./min.)
2.5 m/s (500 ft./min.)
2.0 m/s (400 ft./min.)
1.5 m/s (300 ft./min.)
1.0 m/s (200 ft./min.)
0.5 m/s (100 ft./min.)
70
Lineage Power
April 2008
A
80
(°C)
90
8-1150 (C).a
100

Related parts for JW150H1