JFW150A1 Lineage Power, JFW150A1 Datasheet

no-image

JFW150A1

Manufacturer Part Number
JFW150A1
Description
CONVERTER DC/DC 5V 150W OUT
Manufacturer
Lineage Power
Series
JFWr
Type
Isolatedr
Datasheet

Specifications of JFW150A1

Output
5V
Number Of Outputs
1
Power (watts)
150W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 30A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
150W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JFW150A1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JFW150A1
Manufacturer:
LUCENT
Quantity:
292
Data Sheet
April 2008
The JFW-Series Power Modules use advanced, surface-
mount technology and deliver high-quality, efficient, compact
dc-dc conversion.
Applications
n
n
n
n
Options
n
n
n
Description
The JFW-Series Power Modules are dc-dc converters
that operate over an input voltage range of 36 Vdc to
75 Vdc and provide a precisely regulated dc output.
The output is fully isolated from the input, allowing ver-
satile polarity configurations and grounding connec-
tions. The modules have maximum power ratings from
50 W to 150 W at typical full-load efficiencies of 84%.
The sealed modules have metal baseplates for excel-
lent thermal performance. Threaded-through holes are
provided for easy mounting or adding a heat sink for
high-temperature applications. Listed above are the
enhanced features for convenience and flexibility in
redundant and/or distributed power applications.
Redundant and/or distributed power architectures
Workstations
Computer equipment
Communications equipment
Heat sinks available for extended operation
Choice of primary remote on/off logic configuration
Delayed current-limit shutdown
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 W to 150 W
JFW050A, JFW075A, JFW100A, JFW150A Power Modules:
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
* ISO is a registered trademark of the International Organization of
† UL is a registered trademark of Underwriters Laboratories, Inc.
‡ CSA is a registered trademark of Canadian Standards Assn.
§ This product is intended for integration into end-use equipment.
Standardization.
All the required procedures for CE marking of end-use equip-
ment should be followed. (The CE mark is placed on selected
products.)
Small size: 61.0 mm x 57.9 mm x 12.7 mm
(2.40 in. x 2.28 in. x 0.50 in.)
High power density
High efficiency: 84% typical
Low output noise
Constant frequency
Metal baseplate
2:1 input voltage range
Anti-rollback circuit
Overcurrent protection
Current-limit set-point adjustment
Primary and secondary remote on/off
Remote sense
Adjustable output voltage: 60% to 110% of V
Output overvoltage protection
Overvoltage set-point adjustment
Synchronization
Forced load sharing (parallelable)
Parallelable with FW300A1
Output current monitor
Overtemperature protection
Power good signal
Thermal warning signal
Case ground pin
ISO* 9001 Certified manufacturing facilities
UL
Certified, and VDE 0805 (EN60950, IEC950)
Licensed
CE mark meets 73/23/EEC and 93/68/EEC direc-
tives
1950 Recognized, CSA
§
C22.2 No. 950-95
O, nom

Related parts for JFW150A1

JFW150A1 Summary of contents

Page 1

Data Sheet April 2008 JFW050A, JFW075A, JFW100A, JFW150A Power Modules: dc-dc Converters Vdc Input, 5 Vdc Output 150 W The JFW-Series Power Modules use advanced, surface- mount technology and deliver high-quality, efficient, compact dc-dc ...

Page 2

... I, max I — — I, max I — — I, max — — I — — — 60 April 2008 Unit 75 Vdc 80 Vdc 100 V Vdc 100 °C 125 °C Max Unit 75 Vdc 1.7 A 2.6 A 3.5 A 5.2 A 2.2 A 3.5 A 4 — mAp-p — dB Lineage Power ...

Page 3

... Settling Time (V < 10% of peak deviation Consult your sales representative or the factory. † These are manufacturing test limits. In some situations, results may differ. Table 3. Isolation Specifications Parameter Isolation Capacitance Isolation Resistance Lineage Power (continued) Device Symbol All V O, set All V All — ...

Page 4

... Min Typ Max 2,000,000 — — 100 (3.5) Min Typ Max 0 — 1.2 — — 1.0 — — 15 — — 50 — — — 0.5 60 — 110 %V 5.9* — 7.0* 50 — 100 %V Lineage Power Unit hr g (oz.) Unit µ nom V O, clamp, nom ...

Page 5

... For guidance on appropriate soldering, cleaning, and drying procedures, refer to Lineage Power Board-Mounted Power Modules Soldering and Cleaning Application Note (AP97-021EPS). Lineage Power Symbol — ...

Page 6

... Room Temperature 3.5 3.0 2.5 2 1.5 1 0.5 0 (V) I 8-2247 (C) Figure 3. Typical JFW100A Input Characteristics 7 1 (V) I 8-2248 (C) Figure 4. Typical JFW150A Input Characteristics at April 2008 INPUT VOLTAGE, V (V) I Room Temperature 16 INPUT VOLTAGE, V (V) I Room Temperature Lineage PowerLineage Power 70 80 8-2249 ( 8-2250 (C) ...

Page 7

... OUTPUT CURRENT, I Figure 5. Typical JFW050A Output Characteristics at Room Temperature 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1 1.0 0.5 0 OUTPUT CURRENT, I Figure 6. Typical JFW075A Output Characteristics at Room Temperature Lineage Power 5.0 4.5 4.0 3.5 3.0 2 2.0 1 1 (A) O 8-2251 (C) Figure 7. Typical JFW100A Output Characteristics 5 ...

Page 8

... O 8-2256 (C) Figure 12. Typical JFW150A Converter Efficiency April 2008 OUTPUT CURRENT, I (A) O vs. Output Current at Room Temperature 0.2 0.4 0.6 0.8 1.0 1.2 1.4 OUTPUT CURRENT, I (A) O vs. Output Current at Room Temperature 20 18 8-2257 (C) 1.6 1.8 8-2258 (C) Lineage Power ...

Page 9

... Eliminate Ripple Component.) 1330 μF 830 μF NO CAP 8-2260 (C) TIME ms/div) Note: Tested with an aluminum capacitor as indicated above and a 1.0 µF ceramic capacitor across the load. Figure 16. Typical Start-Up from Remote On/Off JFW150A1; I TIME, t (200 μs/div) 8-2261 (C) 9400 μF 4630 μF 8-2262 ( max ...

Page 10

... The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units provided with a maxi- % mum 20 A normal-blow fuse in the ungrounded lead. April 2008 pin and one V pin are to be grounded Lineage Power ...

Page 11

... Positive logic turns the module on during a logic high and off during a logic low. Lineage Power Negative logic remote on/off turns the module off during a logic high and on during a logic low. Negative logic (code suffix 1) is the factory-preferred configuration. ...

Page 12

... TRIM pin) enables the user to O TRIM pin and either the O TRIM pin O TRIM and O ), the output voltage set point adj-down V (+) O SENSE(+) V TRIM adj-down SENSE(–) V (–) O Output Voltage 100 ⎛ ⎞ kΩ = --------- - 2 – ⎝ ⎠ Δ% Lineage Power LOAD 8-748 (C).e ...

Page 13

... The test results for this configuration are displayed in Figure 25. Lineage Power The voltage between the V must not exceed the output overvoltage shutdown volt- age. This limit includes any increase in voltage due to remote-sense compensation and output voltage set- point adjustment (trim) ...

Page 14

... Schottky diodes are not needed. An internal anti-rollback circuit prevents either output voltage from falling more than 1 V below the other dur- ing light load operation. April 2008 (–). If the I (–) I Lineage Power ...

Page 15

... FW300x modules, consult the factory for the V/A ratio. The output impedance of this pin is approximately 20 k¾, so customer detection circuitry must have a high-impedance input. Lineage Power Overtemperature Protection These modules feature an overtemperature protection circuit to safeguard against thermal damage. The cir- cuit shuts down and latches off the module when the maximum case temperature is exceeded ...

Page 16

... For additional information regarding this module, refer to the Lineage Power Thermal Management JC-, JFC- , JW-, and JFW-Series 150 W Board-Mounted Power Modules Technical Note (TN97-008EPS). Heat Transfer Without Heat Sinks Increasing airflow over the module enhances the heat transfer via convection ...

Page 17

... OUTPUT CURRENT, I Figure 29. JFW050A Power Dissipation vs. Output Current at 25 ° OUTPUT CURRENT, I Figure 30. JFW075A Power Dissipation vs. Output Current at 25 °C Lineage Power (continued) 20 (continued Figure 31. JFW100A Power Dissipation vs (A) O 8-1182 ( Figure 32. JFW150A Power Dissipation vs. Output (A) O 8-1183 (C) Heat Transfer with Heat Sinks The power module has through-threaded ...

Page 18

... JFW150A module is about 1.3 m/s (260 ft./min.). 1 1/2 IN. HEAT SINK 1 IN. HEAT SINK 1/2 IN. HEAT SINK 1/4 IN. HEAT SINK NO HEAT SINK 2.0 2.5 3.0 (400) (500) (600) 8-1153 (C).a April 2008 = 54 V and an output current ° ° using Figure 32 – ----------------------- - – ----------------------- - = 17 = 2.6 °C/W Lineage Power ...

Page 19

... P D Lineage Power This equation assumes that all dissipated power must (continued) be shed by the heat sink. Depending on the user- defined application environment, a more accurate model, including heat transfer from the sides and bot- tom of the module, can be used. This equation pro- vides a conservative estimate for such instances ...

Page 20

... SENSE(–) 5.08 (0.200) TEMPWARN ON/OFF OCTRIM PWRGOOD PARALLEL V (+) I 4.8 (0.19) 48.3 (1.90) April 2008 5.3 (0.21) MIN 7.62 (0.300) MOUNTING INSERTS M3 x 0.5 THROUGH, 4 PLACES V (-) O 35.56 (1.400) SENSE(+) VoTRIM OVTRIM 12.70 CURMON (0.500) S-ON/OFF V (+) O Lineage Power 8-1397 (C).b ...

Page 21

... Converters Vdc Input, 5 Vdc Output 150 W Recommended Hole Pattern Component-side footprint. Dimensions are in millimeters and (inches). 35.56 (1.400) 5.08 (0.200) 5.08 (0.200) 50.8 (2.00) 12.7 (0.50) Lineage Power 57.9 (2.28) MAX 4.8 48.3 (1.90) (0.19) V (+) I ON/OFF 5.08 (0.200) SYNC IN SYNC OUT CASE 10 ...

Page 22

... W Negative 150 W Negative 50 W Positive 75 W Positive 100 W Positive 150 W Positive JFW150A JFW150A1 JFW150A31 Suffix 3 1 — April 2008 Device Comcode Code JFW050A1 108225152 JFW075A1 108247974 JFW100A1 108298977 JFW150A1 108008921 JFW050A TBD JFW075A TBD JFW100A TBD JFW150A TBD Lineage Power ...

Page 23

... Dimensions are in millimeters and (inches). 1/4 IN. 1/2 IN. 1 IN. 61 (2.4) 1 1/2 IN. 57.9 (2.28) Figure 35. Longitudinal Heat Sink Lineage Power 61 (2.4) 8-2832 (C) Figure 36. Transverse Heat Sink Comcode 407243989 407243997 407244706 407244714 407244722 407244730 ...

Page 24

... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...

Related keywords