HW025FG Lineage Power, HW025FG Datasheet - Page 2

no-image

HW025FG

Manufacturer Part Number
HW025FG
Description
CONVR DC/DC 2.5/3.3V 25W OUT T/H
Manufacturer
Lineage Power
Series
HWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of HW025FG

Output
3.3V, 2.5V
Number Of Outputs
2
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 4A
2nd Output
2.5 VDC @ 4A
Size / Dimension
2.26" L x 2.14" W x 0.29" H (57.4mm x 54.4mm x 7.4mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
83%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
13 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
4 A
Output Voltage (channel 2)
2.5 V
Output Current (channel 2)
4 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
3.3 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
No
HW025 Dual Positive Output-Series Power Modules: dc-dc Converters:
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a normal-blow fuse with a maximum rating of 3 A (see Safety Considerations section). Based on
the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse
with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
36 Vdc to 75 Vdc Input, Dual Positive Outputs; 25W
Input Voltage:
Operating Ambient Temperature
Storage Temperature
I/O Isolation Voltage
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
EMC, EN55022
(See Thermal Considerations section)
(V
and 2.)
(5 Hz to 20 MHz, 12 µH source impedance;
see Figure 15)
(V
Continuous
Transient (2ms)
I
I
,
= 0 V to 75 V; I
nom
, full load)
Parameter
O
Parameter
= I
O
,
max
; see Figures 1
Symbol
V
Symbol
I, trans
T
T
V
I
stg
A
I, max
I
V
I
I
I
See EMC Considerations section.
Min
36
Min
–40
–55
Typ
48
54
4
1500
Max
100
100
105
80
Max
1.1
1.0
75
Data Sheet
April 2008
Lineage Power
Unit
Vdc
Vdc
°C
°C
mAp-p
V
Unit
Vdc
A
dB
A
2
s